background image

www.traxontechnologies.com | www.osram.us/traxon

©2022 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS 
PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Installation Guide

01/22 V1.0

13 of 20

3.3.1  

Mounting ARCHISHAPE

®

 2.0 Dot S/M/L

1.  ARCHISHAPE

®

 2.0 Dot S/M/L must be mounted ensuring that no stress is placed on the cable. Follow the 

data provided in section 3.2.3  

2.  ARCHISHAPE

®

 2.0 Dot S/M/Ls MUST be mounted to the installation surface via the mounting holes, either by 

screw or cable tie.

FIG.9:  Mounting the ARCHISHAPE® 2.0 Dot S/M/L

1

2b-3

“click”

2a AS 2.0 Dot M/L mounting

2b-1 AS 2.0 Dot S mounting

2b-2

Screws are provided by others

Screws are provided by others

 

Summary of Contents for traxon ecue ARCHISHAPE 2.0 Dot S

Page 1: ...ARCHISHAPE 2 0 Dot S M L INSTALLATION GUIDE V1 0 Cover ARCHISHAPE 2 0 Dot S M L ETL ...

Page 2: ...PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide 01 22 V1 0 2 of 20 Content 1 Safety And Operation 3 2 Introduction 4 3 Installation 9 4 System Configuration 15 5 Care and Maintenance 17 6 Technical Specification 18 7 Troubleshooting 19 8 Warranty Statement 19 For your own safety and that of the product please read this installation guide carefully before beginning se...

Page 3: ... indoor and outdoor use 5 Ensure product operates within the specified temperature range Refer to 6 TECHNICAL SPECIFICATION for more details 6 Do not attempt to open the product Not user serviceable 7 Do not use the product if any part of it or the power cables are damaged 8 Only use product for specified voltage do not exceed Refer to 6 TECHNICAL SPECIFICATION for more details 9 Always maintain c...

Page 4: ... 1 General ARCHISHAPE 2 0 Dot is a high brightness fully customizable media dot solution available in S M or L with Clear or Diffused View lens to meet your project specifications Each Dot is individually addressable making ARCHISHAPE 2 0 Dot a durable scalable solution for vivid accents graphics and video playback in installations of any size and complexity Features DMX512 Control Daisy Chain Sys...

Page 5: ... AS 2 0 Dot S AS 2 0 Dot M AS 2 0 Dot L Diffused View 10mm 0 39 29 3mm 1 15 14 3mm 0 56 10mm 0 39 29 3mm 1 15 14 5mm 0 57 35 5mm 1 40 53mm 2 09 26mm 1 02 19mm 0 75 12mm 0 47 12mm 0 47 52 2mm 2 06 41mm 1 61 40mm 1 57 φ68mm 2 68 4 x φ 3 3 m m 0 1 3 12mm 0 47 55mm 2 17 41mm 1 61 4 x φ 3 3 m m 0 1 3 φ71mm 2 80 45mm 1 77 19mm 0 75 53mm 2 09 26mm 1 02 12mm 0 47 4 x φ 3 3 m m 0 1 3 41mm 1 61 40mm 1 57 φ6...

Page 6: ...R 30mm 1 18 17 1mm 0 67 15 6mm 0 61 Interconnection Cable AM460720055 FEMALE CONNECTOR FEMALE CONNECTOR 18mm 0 71 47 2mm 1 86 1000mm 3 28 47 2mm 1 86 12mm 0 47 18mm 0 71 AS Dot S Mounting Clip AM357440055 19mm 0 75 29 3mm 1 16 10mm 0 39 1 9mm 0 08 3 6mm 0 14 Auto addressing module 4ch AM345890055 3ch AM456250055 4X 5mm 0 20 67 5mm 2 66 61 5mm 2 42 106 5mm 4 19 18mm 0 71 48mm 1 89 170mm 6 69 170mm ...

Page 7: ...r Injector Cable Kit AM460710055 45 5mm 1 79 7 2mm 0 28 TIGHTENING TORQUES 0 7 0 9N m 18mm 0 71 12mm 0 47 17 7mm 0 70 22mm 0 87 59 2mm 2 33 18mm 0 71 MALE CONNECTOR MALE CONNECTOR FEMALE CONNECTOR 300mm 20mm 11 81 0 79 47mm 1 85 150mm 10mm 5 91 0 39 48mm 1 89 48mm 1 89 FIG 3 ARCHISHAPE 2 0 Dot S M L String FEMALE CONNECTOR MALE CONNECTOR 150mm 5 91 47 2mm 1 86 18mm 0 71 18mm 0 71 500mm 19 69 48mm ...

Page 8: ...S OF TRAXON TECHNOLOGIES U S PATENTS E U PATENTS JAPAN PATENTS OTHER PATENTS PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide 01 22 V1 0 8 of 20 2 3 Packing Contents FIG 4 ARCHISHAPE 2 0 Dot S M L Packing Contents ARCHISHAPE 2 0 Dot S M L FIG 5 RJ45 Power Injector Cable Kit Contents RJ45 Power Injector Cable Kit ...

Page 9: ...Checklist 1 Prepare cables and all necessary accessories 2 Perform functional check of ARCHISHAPE 2 0 Dot S M L 3 Ensure the connector of last dot is covered by the End Cap Resistor 4 Ensure all pre installation checks laid out below have been followed 5 Mount the ARCHISHAPE 2 0 Dot S M L on site If the installation is to be left uncompleted overnight place all non connected LED Engines and ARCHIS...

Page 10: ... Minimum Bending Radius 14mm 0 55 20mm 0 79 D Ø7mm 0 28 50mm 1 97 Minimum Bending Radius 28mm 1 00 4 D The flat ARCHISHAPE 2 0 Dot S M L Cable must NOT be bent twisted below 20mm 0 79 from edge of ARCHISHAPE 2 0 Dot S M L housing Non Bendable Non Twistable Length Twisting the flat cable is NOT recommended If twisting is necessary for installation please adhere to the Non Twistable Length specified...

Page 11: ...to 3 2 3 Requirements Of Cable Bending And Twisting on page 10 as well as Fig 11 on page 14 2 Always keep the End Cap Resistor safe in a container for reuse 3 Connect ARCHISHAPE 2 0 Dot S M L with system components and LED Engines as outlined within this guide See section 4 for System Diagrams 4 Perform functional check on all ARCHISHAPE 2 0 Dot S M L and inspect cables for any damage Check for an...

Page 12: ...nditions DO NOT leave and expose any ARCHISHAPE 2 0 Dot S M L or LED Engine unconnected under wet raining or snowing environment DO NOT pull on cable of ARCHISHAPE 2 0 Dot S M L IP failure induced by stressed damaged cables during or after installation will not be warrantied by Traxon Technologies ALWAYS keep the cables protected from sharp objects and ensure no damage is generated on the cable Fa...

Page 13: ...de 01 22 V1 0 13 of 20 3 3 1 Mounting ARCHISHAPE 2 0 Dot S M L 1 ARCHISHAPE 2 0 Dot S M L must be mounted ensuring that no stress is placed on the cable Follow the data provided in section 3 2 3 2 ARCHISHAPE 2 0 Dot S M Ls MUST be mounted to the installation surface via the mounting holes either by screw or cable tie FIG 9 Mounting the ARCHISHAPE 2 0 Dot S M L 1 2b 3 click 2a AS 2 0 Dot M L mounti...

Page 14: ...ding Length 4 Secure the excess cable between Dots every 500mm 19 7 using cable tie to ensure no damage is generated due to hanging cable FIG 10 Securing the cable Observe clearance Cable tie Mounting surface 5 If the cable between ARCHISHAPE 2 0 Dot S M L requires twisting due to a change in mounting direction ensure the mounting pitch after twisting is more than or equal to 75 of the normal Dot ...

Page 15: ...lation Guide 01 22 V1 0 15 of 20 4 System Configuration FIG 12 System Diagram Basic End Cap Resistor AM345880055 DMX In AC in RJ45 Power Injection Cable Kit AM357480055 LED Engine 24V FIG 13 System Diagram Power Injection DMX In AC in Power Injection Cable Kit AM460710055 AC in LED Engine 24V LED Engine 24V RJ45 Power Injection Cable Kit AM357480055 End Cap Resistor AM345880055 Power injection is ...

Page 16: ... 22 V1 0 16 of 20 FIG 14 System Diagram Auto addressing Module Auto addressing module 4ch AM345890055 3ch AM456250055 DMX In AC in LED Engine 24V RJ45 Power Injection Cable Kit AM357480055 End Cap Resistor AM345880055 Auto Addressing requires e cue Controls FIG 15 System Diagram Junction box DMX In LED Engine 100W 24V Outdoor AM175860055 AC 120V 277V In AS Dot Starter Cable 5M White AM345860055 En...

Page 17: ...serious injury or property damage Do not use product s if cables are damaged Do not connect cables and connectors when wet or in wet area Moisture on bare connectors can cause electric shock and damage to product s Do not use product s in extreme heat environment Ensure there is sufficient airflow and use cool air circulation if required Do not drop knock or shake product s Rough handling can dama...

Page 18: ...15lb 73 6g 0 16lb Operating Temperature 20 C to 50 C 4 F to 122 F Storage Temperature 40 C to 80 C 40 F to 176 F 1 Measurement per dot As with all electronic devices LED output degrades over time a term called lumen depreciation This also explains why it is nearly impossible to expect photometric performances of two LED products with different service life spans to be the same The rate of LED degr...

Page 19: ... 0 Dot S M L strings Check for cables wires or unwanted debris covering LED light source Modules are dim Excess products connected Ensure the power supplies are not overloaded due to an excess of products connected Ensure power supply with proper voltage 24v is being utilized Flickering Incorrect power input Excess products connected Ensure the input voltage is correct Ensure the power supplies ar...

Page 20: ...check for the latest updates and changes on the Traxon website 2022 TRAXON TECHNOLOGIES ALL RIGHTS RESERVED Information is subject to change without prior notice www traxontechnologies com www osram us traxon ...