![Osram AB444200035 Setup Manual Download Page 10](http://html1.mh-extra.com/html/osram/ab444200035/ab444200035_setup-manual_1656605010.webp)
10
General device description
e:net
Off: no link available.
On: link established.
Blinking: e:net traffic.
Error
Off: no error detected.
On: If constantly lights in red, an error occurred. This
can be an internal error or malfunction of the device, or
an external error, e.g. a shortcut of interface
connections or alien power supply. Switch the device off
and on. If the error persists, check the wiring or contact
OSRAM Service.
Error
The Status and Error LED blink simultaneously to
identify the SYMPL Node (enabled “Identify Interface
Mode” in SYMPHOLIGHT).
Input status 1
to 8
Off: Input value is smaller than the Digital Threshold
Low.
On: Input value is bigger than the Digital Threshold
High.
(Change the Digital Thresholds in the properties of the
Node in the Setub Tab of SYMPHOLIGHT).
2.4
Identify button: Identification & Reset
The Identify button has four functions: to send an Identify message (A) and
to reset the Node (B).
(A)
A short press during operation in online mode sends an Identify
message to the server. This helps to assign the Node in the Layout in
SYMPHOLIGHT.
(B)
The Identify button can also be used to reset the device to factory state
or to stay in bootloader mode:
•
Keep the Identify button pressed while powering up, Status and
Error light up at first. Bootloader mode is signaled by a fast blinking
Summary of Contents for AB444200035
Page 6: ...06 English...
Page 22: ...22 Deutsch...
Page 38: ...38 Dimensions Abmessungen All dimensions in mm Alle Abmessungen in mm 62 53 5 90 5...