5
2.4 Technical data
NRF no. Product code:
IP
class
Capacity
persons
Weight
kg.
Dia. x Height
mm.
Freight
vol. m³
Heating time
hours
D
t 65°C
Heat
loss W
8000461 W 30 - 2kW/1x230V
IP21
1.0
12
ø435 x 542
0.13
1.0
-
8000462 W 50 - 2kW/1x230V
IP21
1.5
16
ø435 x 705
0.17
1.6
-
8000463 W 80 - 2kW/1x230V
IP21
2.0
21
ø435 x 1025
0.24
2.8
-
8000464 W 100 - 2kW/1x230V
IP21
5.0
26
ø435 x 1245
0.25
3.3
-
8000465 W 120 - 2kW/1x230V
IP21
2.5
34
ø435 x 1485
0.31
4.0
-
2.5 ErP data - Technical Data Sheet
Brand
Model-no.
Model name
Tap
profile
ErP
Rating
Energy
eff. %
AEC
kWh/a
Thermo-
stat set-
ting °C
Volume
40°C
water
OSO Hotwater AS
8000461
Wally - W 30
S
C
34.2
539
70
52
OSO Hotwater AS
8000462
Wally - W 50
M
C
37.1
1384
70
84
OSO Hotwater AS
8000463
Wally - W 80
M
C
36.4
1411
60
113
OSO Hotwater AS
8000464
Wally - W 100
L
C
38.6
2653
60
142
OSO Hotwater AS
8000465
Wally - W 120
L
C
38.0
2694
60
187
Directive: 2010/30/EU Regulation: EU 812/2013
Directive: 2009/125/EC Regulation: EU 814/2013
Efficiency-tested according to standard: EN 50440: 2015
2. PRODUCT DESCRIPTION
2.1 Product identification
Identification details for your product can be found
on the type plate fixed to the product. The type
plate contains details of the product in accordance
with EN 12897:2016 and EN 60335-2-21, as well as
other useful data. See Declaration of Conformity at
www.osohotwater.com for more information.
OSO products are designed and manufactured in
accordance with:
• Pressure vessel standard
EN 12897:2016
• Safety standard
EN 60335-2-21
• Welding standard
EN ISO 3834-2
OSO Hotwater AS is certified for
• Quality
ISO 9001
• Environment
ISO 14001
• Work environment
ISO 45001
2.2 Intended use
The Wally series is designed to supply homes with
hot running water. The product is designed for in-
stallation on a wall, but can also stand on the floor.
2.3 CE marking
The CE mark shows that the product complies
with the relevant Directives. See Declaration of
Conformity at www.osohotwater.com for more
information.
The product complies with Directives for:
• Low voltage
LVD 2014/35/EU
• Electromagnetic compatibility EMC 2014/30/EU
• Pressurised equipment
PED 2014/68/EU
The safety valve(s) used must be CE marked and
conform to PED 2014/68/EU.
2.6 Spare parts
NRF no. Designation
Product description:
Dimension
801 5005 RGK 1”
Element - 2 kW/1x230V - 1-tube - Inc 825
Length 320 mm.
800 0207 TS2
Thermostat - 59T/66T 50-75°C 1-phase long stem
2-pole
801 5155 Mains cable
Cable with 1 x plug 2.5# - 2+earth
Length 3 m.
801 5519 Connecting cable Internal cable - 2.5# ,180°C / Saga, fork+fork
Length 205 mm
801 3531 FLEX 27
Flexi-hose bend/straight - for CW/HW supply
1/2” x 1/2”
92094
SV-387 FLEX
Safety valve - 9 bar, ø15mm x 1/2” - 1/2” ext. thread overflow
ø15 mm ring clamp
Summary of Contents for Wally W 100
Page 67: ...3 1 1 1...
Page 68: ...4 1 3 18 90 C 1 2 18 40 10...
Page 71: ...7 3 4 25 40 10 40 10 25 40 3 3 2 7 25 3 4 8 7 7...
Page 73: ...9 25 3 4 6 18 3 5 5 3 5 6 40 10 18...
Page 75: ...11 2 10A 1 5 3 16A 2 5 230 3 6 4 3 6 5 90 C 40 10...
Page 76: ...12 4 1 A B A 4 2 A 4 3 10 5 1 1 4 4 A B C 2 D 4 6 4 90 C 3 A B C 4 5 D 1 90 1 3 4 5 1 2...
Page 78: ...14 6 1 6 OSO Hotwater AS 7 1 AX 1 5 2 a b c RESET 5 a b 2 3 c 75 C 5 OSO 75 C 5 a b c AX...