12
4.1 Filling with water
First check that all pipes are connected correctly.
Then proceed as follows:
A) Open a hot tap – leave it open
B) Open the cold water supply to the product.
Check that the water from the open hot water tap
is flowing freely, without any air locks.
A) Close hot tap.
4.2 Turning on the power
When the cylinder has been filled with water, the
power can be switched on.
A) Insert plug into specified wall socket or turn on
switch/breaker.
4.3 Temperature adjustment of tap water
The outgoing hot water temperature from the
product to the taps in the home is mixed auto-
matically. The home is supplied with water that
maintains a temperature approx. 10°C lower than
the set temperature of the thermostat. For tem-
perature adjustment, see section 5.1.1.
4.4 Checkpoints (min. annual)
A) Check that all pipe connections to/from the
product are tight and not leaking.
B) Check that the power supply to the product is
not at risk of exposure to mechanical, thermal or
chemical damage.
C) Check that any overflow pipe from the safety
valve overflow (2) is clear, undamaged and frost-
free with a fall to the drain.
D) Check that the product is hanging securely ver-
tically and horizontally.
4.6 Handover to end-user
4. INITIAL COMMISSIONING
THE INSTALLER MUST:
Brief the end-user on safety and maintenance
instructions.
Brief the end-user on settings and emptying the
product.
Hand this installation manual over to the end-
user.
Enter contact details on the type plate on the
product.
!
WARNING
The water temperature in the product is up to
90°C and could cause scalding. Before emptying,
a hot tap should be opened to the max. pressure/
temperature for min. 3 minutes.
A) Disconnect the power supply.
B) Shut off incoming cold water supply.
C) Open a hot tap to the maximum
– leave open (prevents a vacuum).
D) Twist the knob on the safety valve (1) approx.
90 degrees anti-clockwise to the open position.
Product emptied. After emptying, close the
4.5 Emptying of water
safety valve by turning the knob (1) further
anti-clockwise. Then close all open taps.
-
+
3
4
5
1
2
Summary of Contents for Wally W 100
Page 67: ...3 1 1 1...
Page 68: ...4 1 3 18 90 C 1 2 18 40 10...
Page 71: ...7 3 4 25 40 10 40 10 25 40 3 3 2 7 25 3 4 8 7 7...
Page 73: ...9 25 3 4 6 18 3 5 5 3 5 6 40 10 18...
Page 75: ...11 2 10A 1 5 3 16A 2 5 230 3 6 4 3 6 5 90 C 40 10...
Page 76: ...12 4 1 A B A 4 2 A 4 3 10 5 1 1 4 4 A B C 2 D 4 6 4 90 C 3 A B C 4 5 D 1 90 1 3 4 5 1 2...
Page 78: ...14 6 1 6 OSO Hotwater AS 7 1 AX 1 5 2 a b c RESET 5 a b 2 3 c 75 C 5 OSO 75 C 5 a b c AX...