6
3.3 Product dimensions
All dimensions in mm.
Product
A*
B (HW) C (CW)
ø
MS 600
2030
1530
260
780
MS 1000
2100
1680
300
1000
Tol/- 5 mm.
* Tol 50/-0 mm.
3. INSTALLATION INSTRUCTIONS
3.1 Products covered by these instructions
MS 600
MS 1000
3.2 Included in delivery
2
3
1
4
C
A B
ø
Ref no. Pcs. Description
1
1
Buffer tank with optional electric peak load
2
1
Installation manual (this document)
3
1
T&P safety valve 10 bar/90-95°C
4
1
Junction box with 3 thermostats