8
Component
Torque
Ring clamp connection to CW/HW (ø15) 40 Nm (+/- 3)
Ring clamp connection to cylinder (ø22) 60 Nm (+/- 5)
Product.
CW
HW
Overflow (2)
DI 200 - 300
1/2” / ø15 mm
ring clamp
1/2” / ø15 mm
ring clamp
3/4” internal
3.5.3 Torque settings
3.5 Pipe installation
3.5.1 Incoming water pressure
The efficiency of the product depends on the in-
coming cold water pressure. The water pressure
should be min. 2 bar and max. 6 bar throughout
the day. Excessive water pressure can be adjusted
by installing a pressure reduction valve.
3.5.2 Fitting cold and hot water pipes (CW-HW)
and overflow pipes
A) Turn the mixer valve to the desired position.
• Tighten ring clamp to the cylinder (see
3.5.3)
B) CW and HW pipes of a suitable size should
be run to the mixer valve and tightened (see
3.5.3)
• For larger pipes, a connector with a 1/2”
internal thread can be used.
C) Overflow pipe (1) > 18 mm inside run to the
safety valve;
• Connected to waste 3/4” internal thread.
• Clear, undamaged and frost-free with a
fall to the drain.
The product is designed to be permanently con-
nected to the mains water supply. Approved pipes
of the correct size should be used for installation.
The relevant standards and regulations must be
followed.
360°
1
1
2