4
1.3 Safety instructions for installers
!
WARNING
The overflow from the safety valve must NOT be sealed or plugged.
!
Any overflow pipe from the safety valve MUST be > 18 mm inside, clear, undamaged and
frost-free with a fall to the drain.
!
Fixed electric fittings should be used for installation in new homes or when changing an
existing electrical setup in accordance with regulations. A mains cable with plug for wall
socket can be used when replacing the product without changing the electrical setup.
!
The mains cable should withstand 90°C. A strain reliever must be fitted.
!
The product should be filled with water before the power is switched on.
!
The relevant regulations and standards, and this installation manual, must be followed.
1.2 Safety instructions for users
!
WARNING
The overflow from the safety valve must NOT be sealed or plugged.
The product must NOT be covered over the cover on the front.
The product must NOT be modified or changed from its original state.
Children must NOT play with the product or go near it without supervision.
!
The product should be filled with water before the power is switched on.
!
Maintenance/settings should only be carried out by persons over 18 years of age, with sufficient
understanding
!
CAUTION
The product must not be exposed to frost, over-pressure, over-voltage or chlorine treatment.
See warranty provisions.
Maintenance/settings should not be carried out by persons of diminished physical or mental capac-
ity, unless they have been instructed in the correct use by someone responsible for their safety.
!
CAUTION
!
The product should be placed in a room with a gully/drain, in accordance with current local
regulations. Alternatively, fit an automatic stop valve with sensor and overflow from safety
valve to drain. Liability for consequential damage will only apply if this is followed.
!
The product should be properly aligned vertically and horizontally, on a floor or wall suitable for
the total weight of the product when in operation. See type plate.
!
The product must have a clearance for servicing of 40 cm in front of the cover / 10 cm over the
mixer valve.
Summary of Contents for 800 0952
Page 147: ...3 1 1 1...
Page 148: ...4 1 3 18 90 C 1 2 18 TEK 40 10...
Page 151: ...7 3 3 1 3 4 TEK 40 10 40 40 40...
Page 153: ...9 15 K 2 6 18 3 5 6 3 5 6 TEK 40 10 18 2...
Page 155: ...11 2 10A 1 5 3 15A 2 5 3 6 4 3 6 5 90 C 40 10...
Page 158: ...14 6 1 6 OSO Hotwater AS 7 2 AX 1 5 2 a b c RESET a b 2 3 c 85 C OSO 85 C a b c AX...