9
RECOMMENDATION
- Allow clearance to the floor. Unscrew the feet a minimum of 15 mm out from the bottom of the
product.
-
Mains power supply cable (1) should be hidden under one of the channels in the bottom of the
product, as shown in illustration.
-
If a non-return valve is fitted a reduction valve and expansion vessel should be fitted to pre-
vent dripping from the safety valve.
-
If the maximum water pressure exceeds 6 bar in a 24-hour period a reduction valve and expansion
vessel should be fitted.
CAUTION
The product shall be placed in a room with a floor drain.
The manufacturer assumes no responsibility whatsoever if this provision is not followed.
The product shall be properly aligned vertically and horizontally, on a floor or wall suitable for
the total weight of the product when in operation. See type plate.
The product shall have a clearance for servicing of 40 cm in front of the electric cover / 10 cm
over the highest point.
WARNING
The product shall be filled with water before the power is switched on.
The discharge pipe from any safety device shall be at least one pipe size larger than the
nominal outlet size of the safety device (< 9m length). The discharge pipe shall have
continuous fall to drain, be uninterruptable and frost-free at all times.
1