Operating instructions PC-30-Vario filter control unit Page: 7
Connecting a Pentair IntelliFlo pump
An IntelliFlo pump can be controlled by the PC-30-Vario
using the Pentair Intellicom controller. Connect the
speed controller to terminals 15-20.
A separate mains power supply must be provided for the
pump. The power supply cannot be provided by the PC-
30-Vario.
There must be a link inserted between the two WSK
terminals (winding protection switch).
Always refer to the operating instructions for the pump.
Connecting a Pentair SuperFlo VS pump
A SuperFlo VS pump can be controlled by the
PC-30-Vario. Connect the speed controller to
terminals 15-23.
A separate mains power supply must be provided
for the pump. The power supply cannot be
provided by the PC-30-Vario.
There must be a link inserted between the two
WSK terminals (winding protection switch).
Always refer to the operating instructions for the
pump.
Connecting a Zodiac FloPro VS pump
A Zodiac FloPro VS pump can be connected directly to
the PC-30-Vario unit. Connect the speed controller to
terminals 15-23.
A separate mains power supply must be provided for the
pump. The power supply cannot be provided by the PC-
30-Vario.
There must be a link inserted between the two WSK
terminals (winding protection switch).
Always refer to the operating instructions for the pump.
On the pump, the speed controller must be connected to
the designated terminals on the back of the user
interface. The speeds required for ECO mode (level 1),
normal mode (level 2) and backwash mode (level 3)
must be assigned to speed levels 1 to 3.