background image

 

Installation and Operating Instructions PC-230-smart                                                                  Page

 3 (10)

 

Function 

The 

 PC-230-smart filter control unit can be used to control the on/off times of a 230V AC 

single-phase filtration. The PC-230-smart features the latest touchscreen technology, which can 
be used to configure the following functions: 

a) 

Switching the system on and off. 

Caution: this does 

not 

perform 

all-pole 

isolation of 

the control unit

 

from the mains supply!

 

b) 

Switching  filter  operation  between  continuous  running  and  automatic  mode 
(timed).

 

 
A green indicator light in the touchscreen identifies that the filtration pump is running. 

c) 

Switching the heating between continuous running and automatic mode.

 

 
While the filter is running, the swimming pool heating is additionally controlled by the 
electronic temperature control system. During  a  break in filter operation, the  heating 
is automatically switched off by the internal interlock. It is possible to connect a safety 
thermal cutout or flow sensor for additional protection against the heater overheating. 
The touchscreen can be used to select the required pool temperature or to switch off 
the heating. 

d) 

Adjusting the system time via the touchscreen.

 

Indicator  lights  in  the  touchscreen  show  when  the  filtration  pump  and  heating  are  running, 
allowing easy checking of the status.

 

The  terminals  for  connecting  an 

  NR-12-TRS-2  electronic  water  level  control  unit 

(part no. 3030000020)  can  be  used  for  convenient  automatic  control  of  the  water  level  in  the 
swimming pool. This also protects the filtration pump from any damage which might arise from 
running the filter installation without water. 

The  terminals  for  connecting  an 

-EUROTRONIK-10  can  be  used  to  upgrade  the  filter 

control unit to an automatic filter and backwash controller. 

Fuses 

 

The  electronic  controller  is  protected  by  a 

0.5A  (slow-blow)

  miniature  fuse  located  on  the 

printed circuit board inside the control unit. A 

3.15A (slow-blow)

 miniature fuse is provided for 

the heating. The customer must fit mains fuses of maximum rating 16A to provide short-circuit 
protection for the filtration pump. 

Control fuse 

Heating fuse 

Summary of Contents for 310.000.1230

Page 1: ...310 000 1230 Technical data Dimensions 220mm x 285mm x 85mm Operating voltage 230V 50Hz Power consumption of control unit 1 5VA approx Switching capacity Pump Heating max 1 0 kW AC3 max 0 4kW AC3 Deg...

Page 2: ...peration 6 Touchscreen 6 Switching the PC 230 smart on and off 6 Changing the operating mode of the filtration pump 6 Changing the heating operating mode 7 Setting the required temperature 7 Setting t...

Page 3: ...tout or flow sensor for additional protection against the heater overheating The touchscreen can be used to select the required pool temperature or to switch off the heating d Adjusting the system tim...

Page 4: ...nnecting a filter pump with speed control We have other controls in our range for this type of pump The factory inserted link between the two terminals labelled Th must be removed when connecting a sa...

Page 5: ...ease see Calibrating the temperature on page 8 The following table can be used for checking the temperature sensor Resistance values of the temperature sensor Temperature Resistance 20 C 5800 Ohm 25 C...

Page 6: ...utton to switch off the unit Changing the operating mode of the filtration pump The Filtration pump button can be used to select the operating mode ON AUTO OFF ON runs continuously AUTO runs under tim...

Page 7: ...decreases the required temperature The displayed value is saved automatically Press the button to return to the home screen Setting the time The clock time can be set by pressing the Time button Press...

Page 8: ...the language Press the Language button Press the individual button to select the required language The symbol identifies which language is currently selected Press the button to return to the Main me...

Page 9: ...ows to adjust the time difference The displayed value is saved automatically Press the button to return to the Time settings menu Change the network settings Press the Network settings button In the N...

Page 10: ...tructions PC 230 smart Page 10 10 PC 230 smart combined with NR 12 TRS 2 and EUROTRONIK 10 Subject to changes April 21 Water level controller for overflow pools with spillway Backwash controller EUROT...

Reviews: