12
—
COLOR TEMP
O
O
O
USR…D56…
D65…D93
Used to select the color temperature that
will become the basis for adjustments.
<USR> Color temperature of user set.
<D56> Color temperature around 5600K
<D65> Color temperature around 6500K
<D93>Color temperature around 9300K
VIDEO (2/2)
R GAIN
O
O
O
0…128…255
Gain elements for RED are adjusted.
G GAIN
O
O
O
0…128…255
Gain elements for GREEN are adjusted.
B GAIN
O
O
O
0…128…255
Gain elements for BLUE are adjusted.
R OFFSET
O
O
O
0…128…255
Offset elements for RED are adjusted.
G OFFSET
O
O
O
0…128…255
Offset elements for GREEN are adjusted.
B OFFSET
O
O
O
0…128…255
Offset elements for BLUE are adjusted.
RESET
O
O
O
“R GAIN”- “B OFFSET” values are reset
to color temperatures values selected in
“COLOR TEMP”.
NOTE:
When adjusting, the item displays of “
BRIGHTNESS
”-“
HUE
” and “
R GAIN
”-“
B OFFSET
” move to
the lower part of the screen.
5.3
AUDIO Sub-menu
The AUDIO sub-menu only applies to RMD4342-HSC and RMD4342-SC.
PARAMETERS
Input Signal
Domain Range
NOTE
CVBS
SD-SDI
HD-SDI
AUDIO (1/5)
AUDIO MON
O
O
O
ON…OFF
Used for headphone. The default of left panel
is set to ON, others is set to OFF. “AUDIO
MON” can be only set from “OFF” to “ON”
,
a reverse cannot be allowed.
MON SOURCE
O
O
O
MET 1…MET 4
Used to set the monitoring audio source
from among audio meters.
For RMD4342-HSC, there are four
audio meters (MET1~MET4).
For RMD4342-SC, there are only two
audio meters (MET1~MET2).
VOLUME
O
O
O
00dB…-30dB…MUTE
Used to adjust the volume value.
“MUTE” changes to a continuous flickering
lasting for 10S.
METER H POS L
O
O
O
000…255
Used to set the horizontal position of left
audio meter.
METER H POS R
O
O
O
000…255
Used to set the horizontal position of right
audio meter. Only used for RMD4342-HSC.
TEST LEV
O
O
O
-18dB…-20dB
Used to set the test level of audio meter.
Summary of Contents for RMD4342-HSC