LMD9014 LCD MONITOR User Manual
—
17
—
*4.
COLOR
Use this setting to choose the color of the UMD text. Available colors are
red
,
green
,
yellow
and
white
. This setting does not affect text color when using UMD text via the Image Video or TSL
protocols (text color is set via the protocols).
*5.
ALIGN
Use this setting to choose the horizontal alignment of the UMD text. UMD text can be justified on
the
left
,
center
or
right
of the screen. This setting is overridden when using UMD text via the
Image Video protocol (alignment is set via Image Video protocol).
*6. UMD Protocol
Use the UMD Protocol menu option to choose the protocol with which the unit receives remote
commands. Currently, four protocols are available.
n
Image Video
Use the Image Video protocol setting when controlling the UMD from an Image Video tally
controller (e.g. TSI-1000) or other controlling device which utilizes the Image Video protocol.
The
UMD ID
,
UMD Name(S/N)
, and
Baud Rate
parameters must be set for each screen in
conjunction with the controlling device.
n
TSL v4.0
Use the TSL v4.0 protocol setting when controlling the UMD from a TSL tally controller, or
other controlling device which utilizes the TSL v4.0 protocol. The
UMD ID
must be set for
each screen in conjunction with the controlling device.
n
TSL v3.1
Use the TSL v3.1 protocol setting when controlling the UMD from a TSL tally controller, or
other controlling device which utilizes the TSL v3.1 protocol. The
UMD ID
must be set for
each screen in conjunction with the controlling device.
n
LOCAL
The static UMD is set by the local unit. The others of UMD Protocol can be set by Local
and the corresponding protocols.
*7.
UMD ID
The UMD ID identifies each screen to the controlling device. When using the TSL protocol, the ID
of each screen should be manually set in conjunction with the controlling device. When using the
Image Video protocol, the ID may be set automatically by the controlling device, after each UMD
is initially identified by UMD Name (see “UMD Name[S/N]” below). Available IDs are
000-255
.
*8.
UMD Name (S/N)
Use this setting to assign a name to each screen when using the Image Video protocol.
The UMD
name is equivalent to the Image Video serial number and is used by the Image Video
controlling device to identify each screen.
The default UMD Name(S/N) is “S00000.” It is
recommended to maintain this naming scheme in order to avoid serial number conflicts with other
Image Video devices on the same serial bus. Each name can be up to 16 ASCII characters.
Press ENTER to edit the UMD. Use the ENTER button to move the cursor. Press ENTER with the
cursor on the character to be changed and use the Up/Down button to scroll through character
options. Press ENTER to choose a character. Press MENU to return to the up menu and save the
UMD setting.
Summary of Contents for LMD9014