OPERATING & INSTALLATION INSTRUCTIONS FOR STRATFORD CF ZERO CLEARANCE WOOD HEATER
45
7.2.1.1
Facing
Heat resistant material such as brick, stone or ceramic tile may be in contact with the zero clearance wood
inbuilt decorative frame.
A
= FIREPLACE
B
= HOT AIR REGISTER
C
D*
E
305 mm
MINIMUM
2.13 m
MINIMUM
200 mm
MINIMUM
*Must be measured from the base of the fireplace
and not from the floor.
WARNING: THE FRONT WALL AND THE SUPPORT
OF THE ZERO CLEARANCE ENCLOSURE ABOVE THE
APPLIANCE
MUST
BE
MADE
OF
NON-
COMBUSTIBLE MATERIAL.
LEGEND
Combustible material allowed in this area
Non-combustible material only in this area
NO HEAT SENSITIVE MATERIAL MAY BE PLACED CLOSER THAN 200 MM ON THE SIDE FROM DOOR
OPENING AND ON THE WALL ABOVE THE ZERO CLEARANCE WOOD INBUILT EXCEPT FOR MANTEL SHELF
AND MANTEL KEY.