Page 36
Installation and Operation Manual - Matrix 2700 Insert
ENGLISH
10.6 Minimum Chimney Height
The top of the chimney should be high enough to be above the air turbulence caused when
wind blows against the house and its roof. The chimney must extend at least 3 ft. (1 m) above
the highest point of contact with the roof, and at least 2 ft.(60 cm) higher than any roof line
or obstacle within a horizontal distance of 10 ft. (3 m). The total system height, from the floor
the appliance is mounted on to the top of the chimney, should never be less than 15 feet
(4.6 m).
2' (0.61 M)
MINIMUM
LESS THAN 10' (3.1 M)
CHIMNEY: 3' (0.92 M)
MINIMUM
2' (0.61 M)
MINIMUM
10' (3.1 M)
MORE THAN 10' (3.1 M)
CHIMNEY: 3' (0.92 M)
MINIMUM
NOTE: HEIGHT ABOVE ANY
ROOF SURFACE WITHIN
10' (3.1 M) HORIZONTALLY
CHIMNEY
CHIMNEY
RIDGE
CHIMNEY: 3' (0.92 M)
MINIMUM
2' (0.61 M)
MINIMUM
2' (0.61 M)
MNIMUM
LESS THAN 10' (3.1 M)
NOTE: NO HEIGHT
ABOVE PARAPET
SHALL BE REQUIRED
WHEN DISTANCE
FROM WALLS OR
PARAPET IS MORE
THAN 10' (3.1 M)
CHIMNEY: 3' (0.92 M)
MINIMUM
MORE THAN 10' (3.1 M)
CHIMNEY
CHIMNEY
CHIMNEY
WALL OR
PARAPET
WALL OR
PARAPET
10.7 Chimney Location
The location of the chimney is crucial for
the proper functioning of the appliance.
The chimney should be installed within the
house rather than up an outside wall and
should rise straight up through the tallest
part of the house. This installation benefits
from being enclosed within the warm house
environment, produce stronger draft,
accumulate fewer creosote deposits and
will be unaffected by cold temperatures or
harsh winds.
Summary of Contents for MATRIX 2700 INSERT
Page 2: ......
Page 6: ...Page 6 Installation and Operation Manual Matrix 2700 Insert ENGLISH CERTIFICATION PLATE ...
Page 50: ...Page 50 Installation and Operation Manual Matrix 2700 Insert ENGLISH 5 Remove the blower ...
Page 57: ...Page 57 Installation and Operation Manual Matrix 2700 Insert ENGLISH NOTES ...
Page 58: ...NOTES ...
Page 59: ......