OSAKA
- OF 33 AZ - OPERATING INSTRUCTIONS - Vr. 01 - PAG. 11
6.2 - CLEANING
We recommend cleaning of the instrument with a slightly wet
cloth using water and not abrasive cleaners or solvents which
may damage the instrument.
6.3 - GUARANTEE AND REPAIRS
This device has a guarantee in form of repair or replacement by
manufacturing defects in materials of 12 months from the date
of purchase.
OSAKA SOLUTIONS automatically void this guarantee and is
not liable for any damages deriving from:
-
Use, installation, or use and handling undue, others
than those described above and, in particular, differs
from the safety requirements established by the
regulations.
-
Use in applications, machines or electrical panels that
do not provide adequate protection against liquids,
dust, grease and electric shocks to the installation
conditions made.
-
The inexperienced handling, and / or alteration of the
product.
-
The installation / use in applications, machines or
electrical panels do not comply with the valid norm.
In case of defective product under warranty or out of that
period, it should contact the post sales service to perform the
necessary steps. Request document repair "RMA" (by mail or
fax) and complete it, is necessary send the RMA and the
device to SAT OSAKA by method prepaid.
7 - TECHNICAL DATA
7.1 - ELECTRICAL DATA
Power supply: 12 VAC/VDC, 24 VAC/VDC, 100..240 VAC +/-
10%
Frequency AC: 50/60 Hz
Power consumption: 3 VA approx.
Input/s: 2 inputs for temperature probes: PTC (KTY 81-121,
990
@ 25 °C) or NTC (103AT-2, 10K
@ 25 °C); 1 digital
input for free voltage contacts
Output/s: 3 relay outputs: OUT1 SPST-NO (16A-AC1, 6A-AC3
250 VAC), OUT2 SPDT (8A-AC1, 3A-AC3 250 VAC), and
OUT3 SPST-NO (5A-AC1, 2A-AC3 250 VAC). 16 A Max. for
common (pin. 1)
Electrical life for relay outputs: 100000 operat. (VDE om.)
Installation category: II
Measurement category: I
Protection class against electric shock: Class II for Front
panel
Insulation:
Reinforced insulation between the low voltage part
(supply H type and relay outputs) and front panel; Reinforced
insulation between the low voltage section (supply type H and
relay outputs) and the extra low voltage section (inputs);
Reinforced between supply and relay outputs; No insulation
between supply F type and inputs.
7.2 - MECHANICAL DATA
Housing: Self-extinguishing plastic, UL 94 V0
Dimensions: 33 x 75 mm, depth 64 mm
Weight: 115 g approx.
Mounting: Flush in panel in 29 x 71 mm hole
Connections: 2,5 mm
2
screw terminals block
Degree of front panel protection : IP 65 mounted in panel with
gasket
Pollution situation: 2
Operating temperature: 0 ... 50 °C
Operating humidity: 30 ... 95 RH% without condensation
Storage temperature: -10 ... +60 °C
7.3
– MECHANICAL DIMENSIONS, PANEL CUT-OUT AND
MOUNTING [mm]
R E C O M M E N D E D
P A N E L C U T O U T
29
7 1
m in . 1 5 m m
m
in
.
1
2
m
m
T
Y
P
E
1
P
A
N
E
L
+
G
A
S
K
E
T
P
A
N
E
L
+
G
A
S
K
E
T
T
Y
P
E
2
B R A C K E T
T Y P E 1
B R A C K E T S
T Y P E 2
8 6
7 4
43
31
3 4
M
A
X
1
2
m
m
M
A
X
2
9
m
m
7.4
– FUNCTIONAL FEATURES
Temperature Control: ON/OFF mode
Defrost control: interval cycles or at programmed times (Real
Time Clock Defrosting) by Electric Heating or hot-gas / reverse
cycle
Measurement range: PTC: -50...150 °C / -58 ... 302 °F;
NTC: -50...109 °C / -58...228 °F
Display resolution: 1 ° or 0,1°
Overall accuracy: +/- 0,5 % fs
Sampling rate: 130 ms.
Display: 4 Digit Red h 12 mm
Endurance time of the internal clock without power supply: 4
hours approx. by internal condenser
Compliance: ECC directive EMC 89/336 (EN 61326), ECC
directive LV 73/23 and 93/68 (EN 61010-1)