OSAKA OPERATING INSTRUCTIONS –COC 30- Page 

7

 

The 

SIF 

parameter can be used to establish whether, when the 

“Slt”  time expires, the injection output switches off even if the 
key is still  pressed down (SIF = OFF, pulse function) and 
therefore one must release the key and then press it in order to 
obtain a new injection,  or if the output remains in any case 
activated until the key is  released (SIF = On, permanent 
function). 
The injection command is also subordinate to a block  time 
between two subsequent steam injections so that the steamer 
can return to its temperature. 
When the injection output is switched off, the time counter set 
under  the 

“Sld” 

parameter starts, during which injection 

commands are not performed. 
The steam injection can also be obtained automatically using 
the 

”SIc”, “SIi” 

and 

“SIt” 

parameters. 

The “SIi” > 0 and “SIt” >0 parameters enable automatic 
injection. 
The “SIc” = 0 parameter establishes the continuous automatic 
cycle  whereas > 0 establishes the automatic injection cycle 
time. 
One can therefore obtain: 
1) Manual steam injection once only when one presses the INJ 
key (“SIi” = 0, “Slc”=0). 
2) Continuous automatic steam injection with injection time = 
“SIt” and pause = “SIi” starting from when the key is pressed. 
The injection cycle only terminates when one presses the INJ 
key or when the steamer or the instrument itself is switched off. 
3) A cycle of automatic steam injections for the time “SIc” with 
injection time = “SIt” and pause = “SIi”, starting from when the 
key is pressed. 
At the end of “SIc” time (or if the INJ. key is pressed again 
before the end of the time or if the steamer or the instrument is 
switched off) the cycle of injections terminates. 

 

 
In order to indicate all the possible conditions, the STEAM INJ 
led operates as follows: 
- OFF : injection not active 
- ON : injection in progress 
- Flashing: automatic injection in progress in the pause status 
(“SIi” time) 
 

4.6 – EXTRACTOR CONTROL 

When the instrument is in the ON status, the EXTR. Key can 
be used to enable/disable the EXTR. output. 
Output activation is therefore indicated by the EXTR. led. 
The extractor is normally intended as the oven’s suction fan, 
however the user could command any other function (revolving 
plate, second light, etc.). 
If the controller is switched off (or in the event of a blackout), 
when it  is switched back on again, the output reverts to the 
status in which it was left. 
All the extractor parameters are contained in the 

“ 

ES” 

group. 

The 

“ESd” 

parameter can be used to decide whether the 

output is  commanded by means of the key (=OFF) only or 
whether the output must be also be switched off when steam 
injection occurs, in order 
to prevent the steam injected being extracted (=On). 
In this case, the output (if on) switches  off when steam 
injection starts and remains switched off for the entire duration 
of injection and even after it finishes for a certain time (in sec.) 
that can be set under the 

“Edt” 

parameter. 

Moreover, using the 

“EAS” 

= On parameter, it is possible for 

the  extractor output to be activated (if it is not already) 
automatically, when cooking is terminated, otherwise it will only 
be commanded manually (=OFF) 
In order to facilitate the command of the single extractor on an 
oven where there are a number or appliances, a relay switch-
type  operation mode is provided, by which it is possible to 
command a  single extractor from any one of the instruments 
installed. 
In order to obtain this operation, the 

“Ec

n” parameter can be 

used to establish the operation of the EXTR output in relation 
to the key as bistable (=OFF) or as monostable (= On). 
Therefore, if one wishes to command a single extractor from 
more than one instrument, it is possible to do so: 
-by connecting the relay output EXTR of the first instrument so 
that it commands the extractor, 
-by programming the first instrument with “ECn”=OFF and all 
the others =On, 
-by connecting the EXTR relay outputs of all the others in 
parallel  and therefore to a digital input of the first one, which 
must have  programmed the operation = 2 (see digital input 
operation). 
 
 

4.7  – AUXILIARY OUTPUT AND AUXILIARY REGULATOR 
(AUX) 

The instrument can also be fitted with a settable auxiliary 
output (AUX). 
All the AUX output control parameters are contained in the 

“ 

AO” 

group. 

The 

“AOF” 

parameter can therefore be used to set the output 

function mode as follows: 
= 0 – no function 
= 1 - output ON: the output switches on/off in correspondence 
with the switching on/off of the instrument. 
= 2 – Auxiliary temperature regulator: the use of the AUX probe 
is essential for this function. 
The regulator operates according to the measurement of the 
auxiliary probe, the auxiliary regulator set 

“SP

A”, the relative 

differential 

“HA

S” and function mode 

“ArF” 

(Heat = H; 

Cool=C). 

 

 
The auxiliary regulator can be used for many applications such 
as temperature controls in other areas of the oven or inside the 
product. 
= 3  – End of cooking signal: the output is enabled when 
cooking  ends and, if desired, also ahead of the time that can 
be set under  the 

“AOt” 

parameter. If the parameter is = 0 it 

obviously activates exactly at the end of cooking. 
The function can be used to command an external end of 
cooking  signal or to command various devices, such as, for 
example, the  actuators that open the oven’s unloading 
hatches. 
Once the output has been activated, it can be deactivated by 
pressing the AUX (DOWN) key. 
= 4 – Activation using the AUX(DOWN) key or digital input: the 
output is activated by pressing the DOWN/AUX key (or by 
activating a suitably programmed digital input). 

Summary of Contents for COC 30

Page 1: ...UNCTIONAL DATA 7 5 MEASUREMENT RANGE TABLE 7 6 INSTRUMENT ORDERING CODE DE 1 INSTRUMENT DESCRIPTION 1 1 GENERAL DESCRIPTION Model COC 30 is a microprocessor based digital controller designed to command ovens particularly those used in bakeries The instrument s main feature is the possibility to have separate control over the temperature and heating powers for the TOP and FLOOR of the oven as well ...

Page 2: ...functions The panel therefore shows all the displays and all the leds to be active with the exception of the Stand by Led off OFF STAND BY meaning that the control device does not activate any control function with the exception of the light command The display is therefore off with the exception of the Stand by led which is lit If the automatic switch on timer is present in the OFF status it is p...

Page 3: ...ng of the CLOCK led and the flashing of the hh mm separation led At the programmed time the control device will switch on automatically To deactivate the switching on timer press the START key for 1 second or switch the instrument on ahead of time If you wish the oven to switch on and switch off automatically in this mode the cooking time must also be programmed once the cEF parameter has been pro...

Page 4: ...s possible to the instrument and located in a position that can easily be reached by the user and marked as instrument disconnecting device which interrupts the power supply to the equipment It is also recommended that all the electrical circuits connected to the instrument must be protect properly using devices ex fuses proportionate to the circulating currents It is strongly recommended that cab...

Page 5: ...taneously on therefore if the two resistances are equal the maximum power absorbed is 50 This occurs in any case when without the limiter being on the sum of the two powers is less than 100 Therefore the function with the power limiter on starting from the count of the cycle time is as follows 1 the TOP output remains on for the time tCP 2 x OP1 100 2 Both outputs remain off for the time tCP 2 tCP...

Page 6: ...ill activate when the temperature value rises above the AnH alarm threshold and will deactivate when it drops below the AnH HAn value 4 4 OVEN LIGHT CONTROL The LIGHT key can be used to activate deactivate the LIGHT output the activation of the output is therefore indicated by the LIGHT led When the controller is switched off the output is in any case switched off but in standby mode the output ca...

Page 7: ...eam injected being extracted On In this case the output if on switches off when steam injection starts and remains switched off for the entire duration of injection and even after it finishes for a certain time in sec that can be set under the Edt parameter Moreover using the EAS On parameter it is possible for the extractor output to be activated if it is not already automatically when cooking is...

Page 8: ...ands the extractor connecting the EXTR relay outputs of all the others in parallel and therefore at the digital input of the former which will have suitably programmed the digital input with this operation mode 4 9 RS 485 SERIAL INTERFACE The instrument can be equipped with a RS 485 serial communication interface by means of which it is possible to connect the regulator with a net to which other i...

Page 9: ...larm 1 0 999 seg 0 38 A2t com Alarm type AL2 Ab dE Ab 39 A2L com Lower threshold alarm 2 99 999 99 40 A2H com Upper threshold alarm 2 99 999 999 41 HA2 com Hysteresis alarm 2 1 999 1 42 A2d com Delay activation of alarm 2 0 999 sec 0 43 Pod com Disabling alarms on switching on 0 999 min 0 St Group steam control parameters Par Description Range Def 44 SPS Steamer regulator Set Point 99 999 130 45 H...

Page 10: ... External alarm signal on input intervention the alarm is activated and the upper display alternately shows AL1 and the temperature measured 2 Auxiliary output AUX remote control the digital input is used for the command of the auxiliary output AUX as described in the AOF 4 operating mode of the auxiliary output 3 steam injection remote control the digital input operates as the instrument s INJ ke...

Page 11: ...R output function in relation to the relative key as bistable OFF or monostable ON In practice bistable operation means that the first time the EXTR Key is pressed the output activates and remains activated whereas the second time deactivates it Monostable operation means that the output is activated only when the key is pressed AO Group AUXILIARY OUTPUT PARAMETERS for setting the AUX output AOF A...

Page 12: ...with a detailed description of the faults found without any fees or charge for OSAKA except in the event of alternative agreements 7 TECHNICAL DATA 7 TECHNICAL DATA 7 1 ELECTRICAL DATA Power supply 24 115 230 VAC 10 Frequency AC 50 60 Hz Power consumption 9 VA approx Input s up to 4 inputs for temperature probes tc J K or RTD Pt 100 IEC 2 wires 3 digital inputs for free voltage contacts Output s U...

Page 13: ...UT RANGE tc J Model C SEn J 50 999 C 58 999 F tc K Model C SEn CrA 50 999 C 58 999 F Pt100 IEC Model D 50 600 C 58 999 F 7 6 INSTRUMENT ORDERING CODE COC 30 a b c d e f g hh a INPUTS TYPE C thermocouples J K D thermoresistances Pt100 b SUPPLY D 230 VAC C 115 VAC A 24 VAC c AUXILIARY PROBE INPUT none A YES d AUXILIARY OUTPUT none R YES e STEAMER PROBE INPUT none V YES f COMMUNICATION INTERFACE No i...

Reviews: