4. How to use
The socket’s PCB is placed in a plastic enclosure (Figure 1).
A multi-color LED indicator and the key to initiate the process of binding with the Lun-R re-
ceiver are placed on the socket’s PCB.
Figure 1. Socket and its cover
The socket transmits periodic test signals to the receiver to confirm its operability. When the
test signals stop, the control panel generates the
socket communication lost
event.
The Socket-R is installed in a single-phase AC outlet with a voltage of 100-240V.
The switched load is connected by its mains power plug into the socket of the Socket-R
socket.
Load switching is performed by the commands of the user (or the CMS operator) or in accor-
dance with the function selected in the control panel (see the control panel operating manual). The
socket supports single and periodic switching modes with a frequency of 0.5Hz or 1Hz.
4.1. Modes Indication
The socket modes displays by multicolored LED:
Binding
– blinking green while waiting for a signal from the Lun-R receiver to register in
the control panel memory;
Bound
– when the binding is completed successfully – turning on red for 2…3 seconds;
Load turned on
– glows red while the load is on;
Load turned off
– glows green while the load is off.
Relay-R
Version en_2
4