1. Purpose
The wireless relay Relay-R (hereinafter referred to as the “relay”) is designed for switching the
load in a single-phase 100-240VAC. The relay is controlled by commands from the "Lun" series Con-
trol Panel (for more details on compatibility, see the Control Panel operating manual) through the
"Lun-R" receiver.
Product is not equipped with built-in cameras and microphones, devices and units for
hidden video and audio recording.
2. Safety Precautions
Only the employees, familiar with the module design, instructed on the safety arrangements
shall be allowed to install, routinely maintain and repair.
The device has an open live parts, representing the danger of electric shock to a person
– it is a terminal block marked as IN. No safety ground. You must turn off the power BE-
FORE connecting and disconnecting the product.
3. Technical specifications
The relay technical characteristics is shown in the Table 1.
Table 1. Technical characteristics
Characteristic
Value
Operating frequency range (depends of modification), MHz
433.05…434.79 or
868.70…869.20
Power radiated by the transmitter, mW
up to 10
The health test signals period, seconds
60
Maximum switching current for resistive load, A
7
Mains supply voltage (50Hz), V
85…305
Power consumption from the mains supply, VA
1.5
Degree of protection provided by enclosure
IP20
Dimensions, mm
66*66*35
Weight, g
200
Relay-R
Version en_2