AutoFire® Kiln Controller
User’s Guide
3
FEATURES AND BENEFITS
Your new Orton AutoFire® Kiln Controller has an extensive list of standard features, a user-friendly operator
interface, and a robust temperature control algorithm. These combine to provide what we believe to be the best
temperature controller for electric kilns and furnaces on the market today. The following is a list of the features
we believe you will find most useful as you begin using your new AutoFire® Kiln Controller:
Thermocouple Type
Choose from Type K, N, or S Thermocouples
(We recommend the use of Type K up to 2100
°
F, Type S above 2100
°
F)
Cone Firings
Easy firing to Cone Numbers 022 - 12, with hold time
(additional 5 to 30 minutes of hold can be added)
Proper Heat Work
Orton’s patented method of adjusting firing to ensure proper heat work
Cone Table
Reference temperatures for each cone number (60
°
C/hr or 108
°
F/hr heating rates)
User Programs
10 “to 20” Ramp/Hold Segments for each program, retained even when power is
turned off
Accurate Control
Proprietary
PID Plus
temperature control algorithm assures more
accurate firings. This also includes Soft Start and Overshoot Control
Delay Start
Automatically starts kiln at a later time (up to 9999 minutes later)
Set-Point Control
Setting hold time at 9999 minutes keeps kiln at set point temperature indefinitely
Firing Speed Control
Speed up or slow down your firing (from -40% to +40%) to better match
the loading of your kiln
Program Review
Review your firing program even while the kiln is being fired
Skip Step
If you want to skip to the next ramp in a User Program.
Calibrate to a Cone
Use Cone Offset to adjust the kiln to fire to a cone to adjust the
firing temperature from -38
°
F to +20
°
F
Temperature Alarm
Kiln Temperature Threshold Alarm can be set to audibly notify you when
a temperature is reached
Power Interruption
Recovery from a power interruption occurs when proper to do so
Temperature Units
Select either Fahrenheit (
°
F) or Centigrade (
°
C) Units
Diagnostics
Audible Alarms and error codes indicate when the controller or the
kiln is not firing correctly
Computer Interface
Program and monitor up to 16 kilns from a Personal Computer
Summary of Contents for AutoFire Plus
Page 38: ...AutoFire Kiln Controller User s Guide 36 Appendix C Temperature Equivalents...
Page 41: ...AutoFire Kiln Controller User s Guide 39 Appendix E Connecting Thermocouples...
Page 42: ...AutoFire Kiln Controller User s Guide 40 Appendix F Typical Wiring Diagrams...
Page 43: ...AutoFire Kiln Controller User s Guide 41...