AutoFire® Kiln Controller
User’s Guide
9
USER Program -
using your controller for custom firing programs.
•
The
Up Arrow
increments the value 0 – 9, or scrolls through selections one at a time.
•
The
Right Arrow
shifts editing digit to the right
,
or scrolls through selections one at a time.
The AutoFire® family of kiln controllers feature
10 segment
user programs for custom firing profiles.
Just follow these simple steps:
(controller temperature is displayed in
°
F)
Step
Press
Description Display
1
USER PROGRAM
Enters the User Program mode. Allows the entering
Usr # (where # is a
of a 'New ' program, or editing of an existing one.
value of 1, 2, 3, or 4)
2
UP/RIGHT ARROWS
Scroll to the desired User Program.
USr1, 2, 3, or 4
3
ENTER
Selects the desired User Program.
rA 1, xxxx - where
Displays the first program segment name, Ramp 1
xxxx is the ramp rate
4
RIGHT ARROW
Selects the digit to be modified. The selected
xxxx
digit will flash.
5
UP ARROW
Scroll the selected digit to the desired value.
0xxx
6 -
Repeat steps 4 & 5 till desired value is displayed
0360- ramp of 360
°
/hr
7
ENTER
Stores the new value and displays the next program
°
F 1 , xxxx - where
segment name, Dwell Temperature (
°
F 1 or
°
C 1) xxxx is dwell Temp.
8
RIGHT ARROW
Selects the digit to be modified. The selected digit flashes xxxx
9
UP ARROW
Scroll the selected digit to the desired value.
1xxx
10 -
Repeat steps 8 & 9 till desired value is displayed
1032 - dwell temp.
of 1032
°
F
11
ENTER
Stores the new value and displays the third program
Hd 1, 0.000
segment name, Dwell Time 1 (Hd 1).
12
RIGHT ARROW
Selects the digit to be modified. The selected digit
0.000
will flash.
13
UP ARROW
Scroll the selected digit to the desired value.
0.120 (2 hour hold)
14
-
Repeat steps 11 & 12 till desired value is displayed
15
ENTER
Stores new value and displays the next program ramp
rA 2, 0000
segment. Skip to Step #17 if no more ramps are desired.
16
Repeat Steps 4-14 for each ramp, dwell temperature, and dwell time desired.
17
STOP/START
Acknowledges completion of the completed program
IdLE
and stores the current program into memory.
18
STOP/START
Starts the current user program just entered
xxxx – (current
kiln temperature)
19
STOP/START
Aborts firing cycle, if necessary during firing
Abrt
Summary of Contents for AutoFire Plus
Page 38: ...AutoFire Kiln Controller User s Guide 36 Appendix C Temperature Equivalents...
Page 41: ...AutoFire Kiln Controller User s Guide 39 Appendix E Connecting Thermocouples...
Page 42: ...AutoFire Kiln Controller User s Guide 40 Appendix F Typical Wiring Diagrams...
Page 43: ...AutoFire Kiln Controller User s Guide 41...