TROUBLESHOOTING
Fireplaces
MODEL
LEDFP-
50 | LEDFP-60 | LEDFP-72
ORTECH reserves the right to modify at any time, without notice,
any or all of our product's
features, designs, components and specifications to meet market changes.
Problem
•
Fireplace does
not provide
heat when
turned on
Possible Cause
•
Thermal switch has been
tripped
•
Wiring is loose
•
Fireplace is defected
Solution
•
Turn unit off and unplug unit for 10 minutes. Plug back in and turn unit
on. If plug cannot be reached, follow directions for tripped circuit breaker
•
Disconnect from power source and inspect wiring for loose connections
and repair or replace if necessary
•
Replace the fireplace
•
Touch panel /
remote control
do not work
•
The front glass is moved
or not secured properly
•
Unplug the appliance. If the appliance is recessed to the wall, shut off
house circuit breaker. Ensure the front glass is in the correct location and
is sitting flat to the appliance touch panel. After 15 seconds, plug or turn
on the appliance to reset it
Important Reminder
To remove the glass, you will notice two screws on front both sides
(right and left) of the fireplace. Once the screws are removed, slide the
glass up and away from the fireplace. When the bottom frame plate is
removed, you will notice one flame motor on right side where the rod
should be in place with the rubber plugs.
Please remember to always have the unit disconnected prior to any
work, always lay glass as well as the unit on a towel or other material
not to damage parts / frame.
This entire process should take no more than 20-30 minutes.