INSTALLATION 

& ASSEMBLY

Wall Mounted Installation

Fireplaces

MODEL

 

LEDFP-

50 | LEDFP-60 | LEDFP-72

LEDFP-40/50/60

Wall Bracket

Illustration

LEDFP-72

Wall Bracket

Illustration

Due to the many different materials used on 
different walls, it is highly recommended that you 
consult your local builder before you install this 
appliance on the wall.

1. Select a location that is not prone to moisture

and is located at least 36" (914mm) away
from combustible materials such as curtain
drapes, furniture, bedding, paper, etc.

2. Have two people hold the appliance against

the wall to determine the final location

3. Place unit face down on a soft, non-abrasive

surface. Remove the bracket from the back of
the unit by removing the screws

4. Mark out location, then mount the bracket(s)

onto the wall using the supplied screws. This
bracket MUST have the hooks facing upward
and be level. It is strongly recommended that
the mounting bracket be screwed into the
wall studs where possible. If the wall studs
cannot be used, ensure that the supplied
plastic anchors to affix the bracket to the wall
and the bracket is adequately secured

5. With the wall mounting bracket installed,

have two people lift the appliance up and
insert the two hooks

6. Check the appliance for stability ensuring that

the bracket will not pull free from the wall

Hard Wiring Installation

Hard Wiring Connection

If it is necessary to hard wire this appliance, a qualified electrician MUST remove the 
cord connection, and wire the appliance directly to the house hold wiring.

This appliance MUST be electrically connected and grounded in accordance with local 
codes. If hard wired, in the absence of local codes, use the current CSA C22.1 
CANADIAN ELECTRICAL CODE in Canada or the current ANSI/NFPA 70 NATIONAL 
ELECTRICAL CODE in the United States.

Cover Plate

Fig. 1

Fig. 2

Screws

Screws

Hook

Hook

Summary of Contents for LEDFP-50

Page 1: ...aces draw more current than small appliances Overheating may occur 2 even if it has not occurred with the use of other appliances 3 If the outlet or face plate is hot discontinue use immediately and have a 3 qualified electrician inspect and or replace the faulty outlets Check the parts list to make sure nothing is missing Dispose of packaging materials properly Please recycle whenever possible To...

Page 2: ...according to the dimensions shown in Fig B on the right 3 Take off the two screws in both sides of the glass panel see Fig C 4 Have two people take the glass panel out of the fireplace box Place it to a soft clean place also see Fig D on the right 5 Have two people move the fireplace box to the wall hole 6 Installation complete see Fig G If the appliance is fully recessed into the wall Use the 6 s...

Page 3: ...ation then mount the bracket s onto the wall using the supplied screws This bracket MUST have the hooks facing upward and be level It is strongly recommended that the mounting bracket be screwed into the wall studs where possible If the wall studs cannot be used ensure that the supplied plastic anchors to affix the bracket to the wall and the bracket is adequately secured 5 With the wall mounting ...

Page 4: ...bble embers are installed 2 If your fireplace come with log set remove the log set from the package put it to the fireplace designed place also see Fig 5 3 If your fireplace come with CLEAN CRYSTAL or PEBBLE MEDIA Crystal or pebbles media may have a fine oil residue that needs to be cleaned prior to installation Clean them with mild dish soap drain rinse thoroughly and dry before placing into the ...

Page 5: ... reset 1 Unplug the power cord from the outlet 2 Turn the ON OFF switch on the control panel to OFF Wait 5 mins 3 Inspect the fireplace to make sure no vents are blocked or clogged with dust or lint If they are use a vacuum to clean the vent areas 4 With the power switch in the OFF position plug the power cord back into the outlet 5 If the problem continues have your outlet and wiring inspected by...

Page 6: ...pect wiring for loose connections Call a qualified service technician to replace flame motor Flame Rod out of place due to rough transit handling of the product This issue can be corrected as simple as removing the glass flipping the fireplace upside down removing a set of screws that are holding the bottom frame plate and placing the flame rod back into place Flame is not visible Wiring is loose ...

Page 7: ...ctions and repair or replace if necessary Replace the fireplace Touch panel remote control do not work The front glass is moved or not secured properly Unplug the appliance If the appliance is recessed to the wall shut off house circuit breaker Ensure the front glass is in the correct location and is sitting flat to the appliance touch panel After 15 seconds plug or turn on the appliance to reset ...

Reviews: