Operator Manual
Cha
pt
er
:
Di
sp
la
y
19
7.
Pre-gas: In the menu in question, it is possible to set the operating mode of the solenoid valve that checks the protection GAS supply.
If OFF is selected, the solenoid valve activates simultaneously with the LASER shot when the pedal is pressed. If ON is selected,
pressing the pedal activates the solenoid valve. Therefore, the pedal must be released and then pressed again to start shooting (Pre-
Gas active).
8.
Firmware update: This menu can be used to update the LASER firmware via the USB pendrive. Remove the USB pendrive from the
connector inside the welding chamber, introduce it into a PC to copy the updating files:
XXSEvoFW.hex
EVOPROG.txt
EVOROM.txt
Warning:
DO NOT open and DO NOT modify these files for any reason whatsoever!
Re-insert the pendrive into the LASER and select the FW Update Menu; Press the Upgrade key: Some phrases appear on the screen that inform
not to remove the power supply because the update is in progress. After a few seconds the screen will become completely white and will remain
in this way for approx. 30 seconds until the update is completed.
When the update has been completed, the initial screen appears and communicates to switch the system off and back on again.
Verify correct updating via the Info Menu.
9.
Service: The menu is protected by Password accessible only to personnel authorised for the maintenance of the device.
10.
Date and Time:
This screen can be used to set the time shown on the display with the machine in Stand-by.
11.
I.U.V.A.P.S.: In this section it is possible to enable the sanitising function by switching the UV lamp on. (OPTIONAL)
Sanitisation
OFF: The machine and the extraction system operate normally and the UVC sanitising light is off.
ON: The UVC lights switch on, thus allowing sanitisation of the environment via normal operation of the equipment fan. This function can be
activated both in ”STANDBY” and in ”START” modes.
PULSED: By pressing the button (PULSED), the "PULSED" function is set, which can only be activated when the machine is in ”STAND-BY”. During
this operation, the fan extracts periodically following two work speeds. In this way, even if the LASER is not used, the environment is sanitised
allowing re-circulation of the air.