8
Fig.1 Power supply diagram
Fig. 2 Special power supply diagram
Reset to factory default
1. Switch off the power.
2. Wait for 10 seconds and restore the power.
3. Immediately press and hold # button.
4. Release the button once you hear “Di Di” sound.
Sound and light indication
Operation status
Red light
Green light
Buzzer
Power on
-
Bright
Di
Stand by
Bright
-
-
Press keypad
-
-
Di
Operation successful
-
Bright
Di
Operation failed
-
-
Di Di Di
Enter into programming mode
Bright
-
Di
In the programming mode
-
-
Di
Exit from the programming mode
Bright
-
Di
Open the door
Bright
Di
Alarm
Bright
Alarm
Detailed programming guide
To enter the programming mode
* Master code #
999999 is the default factory master code
To exit from the programming mode
*
Note that to undertake the following programming the master user must be logged in
To change the master code
0 New code # New code #
The master code can be 6 to 8 digits long
Setting the working mode:
Set valid card only users
Set valid card and PIN users
Set valid card or PIN users
3 0 # Entry is by card only
3 1 # Entry is by card and PIN together
3 2 # Entry is by either card or PIN (default)
To add a user in either card or PIN mode, i.e. in the 3 2 # mode. (Default setting)
To add a Pin user
1 User ID number # PIN #
The ID number is any number between 1 & 2000. The PIN is any four digits between
0000 & 9999 with the exception of 1234 which is reserved. Users can be added
continuously without exiting programming mode as follows:
1 User ID no 1 # PIN # User ID no 2 # PIN #
To delete a PIN user
2 User ID number #
Users can be deleted continuously without exiting programming mode
To change the PIN of a PIN user
(This step must be done out of programming mode)
* ID number # Old PIN # New PIN # New PIN #
To add a card user (Method 1)
This is the fastest way to enter cards, user ID number
auto generation.
1 Read card #
Cards can be added continuously without exiting programming mode