4
3
In the standard delivery the system support locks with Normally Open(N.O.) door
unlocking method. It means that in the normal state the dry contact(marked as )
is opened, so the lock is kept under constant closed state. If the unlocking button
is pressed and the dry contact is changed to closed, then the lock is released.
If the speaker volume is too low, how to increase it?
At the backside of outdoor unit, you can find out a regulator (
Marked as
)
which is used to adjust the speaker volume, turn the regulator with the screwdriver
to decrease/increase the speaker volume.
b
2.4 Installation process of Outdoor Units
The power supply of the IP outdoor camera is provided with the chime, and the
chime is with built-in power supply.
Connect the terminals of the outdoor camera to the terminals of then crystal
head as method B on the following figure.
B. For the chime
Stop
Music
Play
1
1
0
m
m
76mm
1/4 CMOS
o
60
1.0M
o
IR LEDs(60 )
400mA max.
External switching power supply DC12V.
10/100M
-40~+50
℃
Surface
/
flush
mount
o
(
view angle of the model including character “R” can be up to 110
)
Camera
View angle
Definition(Hor.)
LEDs for night
Power consumption
Power supplier
Network Interface
Operation temp.
Installation
25.7mm
600mA max
-40~+60
℃
Surface
mount
Built-in Power supply(AC 100~240V, 50/60HZ)
DC 12V
Output current
Operation temp.
Installation
Power supplier
Output voltage
2.3
Wiring Diagram of the IP Outdoor Camera & chime
The terminal is defined functionality as below:
1.OG&WH: To crystal head OG&WH(B); 2.OG: To crystal head OG(B);
3.GN&WH: To crystal head GN&WH(B); 4.GN: To crystal head GN(B);
5.BK:GND; 6.RD: DC 12V; 7/8.BN: To door lock.
Crystal head
B
A
B
A
5e
C
T568A/B
Antenna(optional)
Antenna connector
(optional)
1.OG&WH
2.OG
3.GN&WH
4.GN
5.
6.
7.BN
8.BN
BK:GND
RD:DC 12V
+
-
Network Cable
To Internet
b
Note: GN--Green, WH--White, OG--Orange, RD--Red, BK--Black, BN--Brown.
B
Built-in power supply
(AC 100V~240V)
J6
GND
VDD
IP Doorbell