background image

7

The company preserves the right to change all specifications of the products and their accessories without prior notice

SOLAR WATER HEATERS

LABELING 

ORKLI

 solar water heaters are identified by two stickers, one of them on the tank and the other on the 

collector. On 

these stickers all the details of the system are written. The information provided on the stickers are important for the 

future identification of the system.

Flat harp solar collector AL 2.0

Colector solar plano arpa AL 2.0

SOLAR BOILER GLASS

ACUMULADOR SOLAR VITRIFICADO

Type: XXX lt / Closed loop

Modelo: XXX lt / Circuito cerrado

S/N: XXXXXX

Fecha: XX / XXXX

IP 23

Capacity / Capacidad: XXX lt

Capacity Closed Loop /

Capacidad del circuito cerrado: XXX lt

Nom. Pressure / Pression nominal: XXX bar

Dimensions LxWxH / Dimensiones LxAxA (mm): 2010 x 1010 x 110
Overall area / Area total: 2,03 m²
Absorber area / Area del absorbedor: 1,81 m²
Overall collector weight / Peso del captador vacio: 32,3 kg
Volume of heat transfer fluid / Volumen del fluido de transmisión térmica: 1,75 lt
Absorber coating: High selective vacuum coating
Absorbedor: Tratamiento altamente selectivo al vacío
Standstill temperature / Temperatura max. de estancamiento: 186 °C
Max. operating pressure / Presion max. de trabajo: 1,0 MPa (10 bar)
Transparent cover / Cubierta transparente: Tempered, low-iron solar glass / Vidrio solar templado

S/N: XXXXXX

Date: ΧΧ / ΧΧΧX

MADE IN EU

MADE IN EU

Summary of Contents for SPT 1-160

Page 1: ...TECHNICAL MANUAL Solar water heaters Installation maintenance use instructions...

Page 2: ......

Page 3: ...AYOUT 11 ORKLI 320lt 4m2 LAYOUT 12 GENERAL INSTALLATION RULES 13 INSTALLATION POSITION 14 GENERAL PREVENTION MEASURES 15 LIGHTNING PROTECTION 15 SUPPORT BASE PARTS 16 SUPPORT BASE ASSEMBLY ON A FLAT S...

Page 4: ...water heater maximum use of hot water should be made during daytime so that the system can continuously produce hot water during the daylight hours maintaining thus its maximum efficiency SOLAR WATER...

Page 5: ...rm their quality They are highly aesthetic systems which can be simply and quickly installed to blend with the traditional or modern architecture of a building and to provide free hot water almost the...

Page 6: ...ears in the following table MODEL ORKLI SPT 1 160 ORKLI SPT 2 320 DESCRIPTION 160lt tank 2 0m2 collector 320lt tank 2 x 2 0m2 collectors SOLAR WATER HEATERS FITTINGS ACCESSORIES 1 COLLECTOR 2 COLLECTO...

Page 7: ...cerrado S N XXXXXX Fecha XX XXXX IP 23 Capacity Capacidad XXX lt Capacity Closed Loop Capacidad del circuito cerrado XXX lt Nom Pressure Pression nominal XXX bar Dimensions LxWxH Dimensiones LxAxA mm...

Page 8: ...nnection cable 11 Cold water inlet 1 2 BSP male threaded pipe end for water stratification and 10 bar safety valve for releasing pressure 12 Hot water outlet 1 2 BSP male threaded pipe end 13 Jacket i...

Page 9: ...manifolds fitting thus avoiding pressure drop in the collectors tube pitch 93mm EN 1652 4 Sun Selective complete area absorber made of selective aluminium sheet with a special titan coating formed in...

Page 10: ...f supporting base system made of 2 5mm thick galvanised steel for installation on flat or inclined surfaces SUPPORT BASE YEARLY ENERGY OUTPUT kWh m2 ATHENS GREECE 614 DAVOS SWITZERLAND 795 W RZBURG GE...

Page 11: ...2 4 1 3 6 5 8 7 1 2 6 5 4 8 7 ITEM Nr PART DIM SIONS QTY 1 Beam L Laminate section 60 x 2 5mm 2060 x 60mm 2 2 Beam L Laminate section 60 x 2 5mm 2250 x 60mm 2 3 Beam L Laminate section 60 x 2 5mm 119...

Page 12: ...5 8 7 1 2 6 5 4 8 7 ITEM Nr PART DIM SIONS QTY 1 Beam L Laminate section 60 x 2 5mm 2060 x 60mm 2 2 Beam L Laminate section 60 x 2 5mm 2250 x 60mm 2 3 Beam L Laminate section 60 x 2 5mm 1190 x 60mm 2...

Page 13: ...formance should be corrected by increasing the collector surface following a study and evaluation of the specific conditions that apply As the sun ray s angle of attack varies with time but also depen...

Page 14: ...for the solar water heater installation INSTALLATION POSITION The installation is only allowed on roofs and flat surfaces of adequate bearing capacity Before you proceed with the installation make su...

Page 15: ...ause accidents Requirements related to the personnel y y The installation of our Solar Thermal systems can only be undertaken by authorized specialized companies and trained personnel y y Works in ele...

Page 16: ...16 The company preserves the right to change all specifications of the products and their accessories without prior notice For 2 0m2 collectors SUPPORT BASE PARTS For 4 0m2 collector 2 x 2 0m2...

Page 17: ...parts of the frame and tighten all screws Repeat steps 1 2 3 for the other pairs of parts SUPPORT BASE ASSEMBLY ON A FLAT SURFACE 1 Screw parts 1 to part 2 using the M8 screws and nuts included in th...

Page 18: ...tank s side where the heating element is located and to the socket marked collector intake 12 Join the other end to the top left socket of the collector using the 22x DN16 INOX corner fitting having f...

Page 19: ...insulation tube Tighten all unions in the system as well as all the screws on the base Do the hydraulic connection fill the closed loop and do the electrical connection as described in the relevant s...

Page 20: ...ctor supporting part 5 to the bottom part of the frame and tighten the screws 4 Screw the collector supporting part 5 to the top part of the frame without tightening the screws 5 Bend the straight par...

Page 21: ...ace the small flexible tube on the special connection DN16 INOX at the water storage tank s side where the heating element is located and to the socket marked collector intake 12 Join the other end to...

Page 22: ...ing firstly passed the tube through the insulation tube Tighten all unions in the system as well as all the screws on the base Do the hydraulic connection fill the closed loop and do the electrical co...

Page 23: ...the closed loop with anti freeze liquid the water storage tank has to be completely filled with water 1 Connect the water mains to the specially designed filling fitting on the right of the water sto...

Page 24: ...to the electrical board using a bipolar disconnection switch with a minimum distance between contacts of at least 3mm The circuit breaker s rating must be suitable for the heating element in use Cauti...

Page 25: ...TILED ROOF WITH THE WATER STORAGE TANK UNDER THE ROOF Natural circulation operation ELECTRICAL COMPONENTS Heating Element Thermostat THERMOSTAT AUTOMATIC AUXILIARY THERMOELECTRIC FUSE This is tripped...

Page 26: ...lity of slow leakage 8 Make sure the hot water supply is not mixing with a cold water supply 9 Make sure the connecting pipes are not kinked 10 Check the level of the antifreeze liquid and top up if n...

Page 27: ...and a hot water tap until the water storage tank fills up 10 Check for water leaks 11 Reconnect the electrical components at their designated positions 12 Check that the thermostat is securely clipped...

Page 28: ...recommended that the glass is washed at an hour of low sunlight to avoid damages due to expansion contraction due to temperature changes y y If the fittings are worn screws pugs piping etc these shou...

Page 29: ...protection on the thermal insulation Is the piping properly insulated Has the installment on the roof been done according to the local regulations HYDRAULIC CONNECTIONS Are there any leaks in the clo...

Page 30: ...30 The company preserves the right to change all specifications of the products and their accessories without prior notice NOTES...

Page 31: ......

Page 32: ...V1 03 14 www orkli es...

Reviews: