1. Settings buttons.
2. Display of measurement of CO2 concentration in ppm in 
the room.
3. Display of the relative humidity of the room.
4. Micro USB charging port for the battery (under the base).
5. Display of the ambient temperature of the room.
6. Battery indicator.

ON/OFF functions to switch the meter on and off.

In standby mode:

 allows you to change how the 

unit of temperature is displayed (°C/°F).

In configuration mode:

 allows you to increase 

the display value by +1.

In standby mode:

 allows you to enable/ disable 

the alarm.

In configuration mode:

 allows you to select the 

display value to the left.

In configuration mode:

 allows you to select the 

display value to the right .

Allows you to record data.

In configuration mode:

 allows you to reduce the 

display value by -1.

In standby mode:

 allows you to select the 

configuration mode.

In configuration mode:

 allows you to confirm 

and move to the next settings.

°C/°F

REC

ALM

Functions of settings buttons:

Summary of Contents for QUAELIS 16

Page 1: ...MESUREUR DE QUALITE DE L AIR INTERIEUR QUAELIS 16 Manuel d utilisation FR MANUEL D UTILISATION...

Page 2: ...t rieur Caract ristiques Techniques Mesure et affichage cran LCD du taux de concentration de dioxyde de carbone en ppm partie par million du taux d humidit relative et de la temp rature ambiante dans...

Page 3: ...glages 2 Affichage de la mesure du taux de concentration de CO2 en ppm de la pi ce 3 Affichage du taux d humidit relative de la pi ce 4 Port micro USB de recharge de la batterie sous le socle de pose...

Page 4: ...t si n cessaire Fonctions ON OFF pour allumer et teindre le mesureur En mode veille permet de changer l affichage de l unit de temp rature C F En mode param trage permet d augmenter la valeur d affich...

Page 5: ...endant quelques minutes avant les r glages et l utilisation afin de bien d gager les capteurs Les mesures s affichent sur l cran lorsque le d compte est termin Mesures et indices de confort pour le CO...

Page 6: ...puis rel cher sur le bouton MODE pour confirmer le r glage du calendrier et passer au r glage de l horaire ALM Des valeurs sup rieures 2000 ppm peuvent entra ner des troubles des occupants de la pi c...

Page 7: ...arme sonore ATTENTION Lors du param trage des seuils pour les alarmes visuelles jaune et rouge la valeur de l alarme visuelle rouge doit tre sup rieure la valeur de l alarme visuelle jaune ATTENTION l...

Page 8: ...pi ce cela peut conduire des niveaux de pollution tr s lev s Il est donc important de veiller ce que l utilisation de la pi ce soit conforme au taux d occupation pr vu puis d am liorer les conditions...

Page 9: ...tallation La premi re page d accueil appara t Appuyer sur le bouton Next Appuyer sur Browse et s lectionner l emplacement du dossier pour enregistrer le logiciel Puis appuyer sur le bouton Next Appuye...

Page 10: ...iquement reconnu Proc der aux param trages des donn es enregistrer avant de lancer l enregistrement des donn es 6 1 Appuyer sur Set Param ou Communication Set Parameters La fen tre s ouvre 6 2 Renseig...

Page 11: ...r Immediate Puis appuyer sur OK 6 9 Valider sur OK lors de la derni re fen tre qui indique que l enregistrement commence The meter is recording data Sur l cran du mesureur REC appara t gauche au dessu...

Page 12: ...High 50 CO2 1200 ppm Attention Le champ Address doit tre en num rique S assurer que l alarme sonore est activ e Les valeurs mini et maxi pour la temp rature et l humidit servent de seuils de r f renc...

Page 13: ...r Le fichier Excel comporte deux onglets un onglet avec les mesures enregistr es Data Record et un onglet avec un rappel des param tres s lectionn s pour l enregistrement Parameters Le message Success...

Page 14: ...rce de chaleur de produit inflammable et de champs magn tiques Maintenir le mesureur teint appuyer sur OFF en cas de non utilisation prolong e Calibrer le mesureur Lorsque le mesureur affiche des vale...

Page 15: ...encontr s D fauts constat s Le mesureur ne s allume pas L alarme visuelle ne se d clenche pas Les seuils de couleurs ne correspondent pas La batterie ne se charge pas Solutions comment r soudre le pb...

Page 16: ...le c ble fourni Le mesureur doit tre correctement allum position ON pour tre reconnu Essayer les deux tapes suivantes Allumer le mesureur et attendre que le temps de pr chauffe soit termin Relier le...

Page 17: ...gas that comes from a variety of sources greenhouse gases transport fuel heating Carbon dioxide CO2 a molecule that is naturally present in the atmosphere is produced by the human body during respira...

Page 18: ...2000 mAh 3 7v USB Cable and 230V adapter supplied Response time 1 second Conditions for use 0 C 50 C 0 85 no condensation Storage conditions 20 C 60 C 0 90 no condensa tion Technology non dispersive...

Page 19: ...and off In standby mode allows you to change how the unit of temperature is displayed C F In configuration mode allows you to increase the display value by 1 In standby mode allows you to enable disab...

Page 20: ...warming up The battery indicator 6 indicates the progress of charging After shipping and removing the protective packaging the product must be placed in a well ventilated area for a few minutes prior...

Page 21: ...oss of consciousness It is recommended not to exceed 2000 ppm as CO2 threshold for red and sound alarms Step 2 Setting alarms Values and color range previously indicated are set by default To customis...

Page 22: ...to set up for red visual alarm and alarm sound Proceed as indicated above to select and change the values of red alarm and sound alarm Press and hold down the MODE button then release to confirm sett...

Page 23: ...al installer screen appears Click on Next Step 5 Install the software The measurements taken by the Quaelis 16 meter can be recorded on a Windows PC It enables up to 12700 measurements up to 500 days...

Page 24: ...tional 44980 Ste Luce sur Loire France 46 Click on Browse and select the folder where you want to install the software Then click on Next Click on Next to confirm installation When the progress bar is...

Page 25: ...t Name fields 6 3 Indicate the total number of readings to be recorded Total Records and the time interval between each reading Interval Select the interval unit in seconds Sec minutes Min or hour Hou...

Page 26: ...surement recorded is higher the threshold of 1200 ppm is highlighted in black Example recording 10 readings every minute in room 1 on PC1 called Measurements so the total recording time is 10 minutes...

Page 27: ...on the PC The chart for the data is displayed To view the different recordings Click on File Open and select the file to view To save in Excel format After opening the file click on File Export Name...

Page 28: ...direct sources of carbon dioxide liquid products heat flammable products and magnetic fields Keep the meter off press OFF if unused for a prolonged period of time Conditions of use and safety Use the...

Page 29: ...8 Keep the meter outside during calibration and do not perform any actions on the meter 9 The calibration process takes several minutes about 10 minutes 10 When calibration is complete the display sh...

Page 30: ...e following two steps Turn on the meter and wait for it to warm up Connect the USB cable and start the software Turn on the meter and wait for it to warm up Start the software Then connect the USB cab...

Page 31: ...r electronic products at the end of their useful lives can have negative effects on human health and the environment They should not be mixed with general household waste For proper treatment recovery...

Reviews: