2. BASIC ADJUSTMENTS
Prepare the following measurement tools for electrical
2-1: WHITE BALANCE
adjustments.
1. Place the set in Aging Test for more than 15 minutes.
1. Pattern Generator
2. Please select input About mode to adjust W/B.
3. Receive the gray scale pattern from the Pattern
On-Screen Display Adjustment
Generator.
4. Press the INPUT SELECT button on the remote control
1. Press the MENU ---> 1147 button on the remote
to set to the AV mode.
control.
5. Using the remote control, set the brightness and
2. Press the DOWN button on the remote control.
contrast to normal position.
3. Select the "Video" menu, then press
6. Press the MENU ---> 1147 button on the remote control.
ENTER button on the remote control.
7. Press the DOWN button on the remote control.
4. Select the "Color Temperature" menu , then press
8. Select the "Video" menu, then press
ENTER button on the remote control.
ENTER button on the remote control.
5. On the screen as shown in
Fig. 1-1.
9. Select the "Color Temperature" menu , then press
ENTER button on the remote control.
10. Press the UP/DOWN button on the remote control
to select the "R Gain", "G Gain", "B Gain", "R Offset",
Color Temperature
Cool
<>
"G Offset", "B Offset.
11. Adjust the LEFT/RIGHT button on the remote control
R Gain
-37
to whiten the R Gain, G Gain, B Gain, R Offset, G Offset,
G Gain
0
B Offset at each step tone sections equally..
B Gain
102
12. Perform the above adjustments 10 and 11 until the white
R Offset
-2
color is achieved.
ELECTRICAL ADJUSTMENTS
1. ADJUSTMENT PROCEDURE
G Offset
0
B Offset
-1
Fig 1-1
D-1