![background image](http://html1.mh-extra.com/html/orion/obdtrac/obdtrac_getting-started_1652442023.webp)
© 2007 ORION Technology LTD. All rights reserved.
23/40
VII.
Function Variables Configuration – Idle Report
1. Type
‘4’
to enter
‘Function Variables Setting Menu’
. Then type
‘4’
to
enter
‘Idle Report Setting Menu’.
The settings are to activate the ‘Idle
Alert and Move Alert’ function.
Main Setting Menu :
1. Basic Setting
2. GSM/GPRS Connection Setting
3. Gateway Server Setting
4. Function Variables Setting
5. Report Settings Setting
E. Exit
Selection [1-3]?
4 <Press Enter>
Function Variables Setting Menu :
1. Mileage Report Setting
4. Idle Report Setting
5. Speed Limit Report Setting
E. Exit
Selection ?
4 <Press Enter>
Idle Report Setting Menu :
1. Idle Report Enable :
NO
2. Idle Duration (sec) :
0
3. Report Time Interval (sec) :
1 : [1(Once)|2-65535]
E. Exit
Selection ?
Idle Report Setting Menu :
Field
Mandatory
Description
Idle report
Enable
5
YES : Enable the tracker to generate ‘$LIDL’ and ‘$LMOV’
event reports.
NO : Disable the tracker to generate ‘$LIDL’ and ‘$LMOV’
event reports.
Default Value = “NO”
Idle
Duration
5
If the GPS speed < 5mph for more than ‘Idle Duration’. It
sends a ‘$LIDL’ event report by every ‘Report Time
Interval’. The unit is ‘second’. Range from “10” to 65535”.
Report
Time
Interval
5
A time interval to keep sending ‘$LIDL’ event reports if the
tracker keep idling. The unit is ‘second’.