background image

 

 

 

 

 

 

 

HCCA102 & 104 Vented 1500+ Watts Input

 

 

 

 

 

Box Properties

 

— 

Description 

— 

Type: Vented Box 

Shape: Prism, Square 

 

— 

Box Parameters 

— 

Vb  

=  

0.75 cu.ft 

V(total) =  

1.007 cu.ft 

Fb  

=  

42 Hz 

QL  

=  

F3  

=  

35.53 Hz 

Fill  

=  

none 

 

— 

Vents 

— 

No. of Vents  

= 1 

Vent shape  

= rectangle 

Vent ends  

= one flush 

Hv  

= 2.5 in. (64 mm) 

Wv  

= 2.5 in. (64 mm) 

Lv  

= 10.95 in. (278 mm) 

 

— 

External Dimensions 

— 

A = 13.5 in. (343 mm) 

B = 13.5 in. (343 mm) 

C = 15.16 in. (385 mm) 

— 

Internal Dimensions 

— 

A = 11.5 in. (292 mm) 

A  

B = 11.5 in. (292 mm) 

C = 13.16 in. (334 mm) 

C  

— 

Wall Thickness 

— 

Front  = 1 in. (25.4mm) 

B  

Sides = 1 in. (25.4mm) 

 

 

 

 

Top & 

Bottom 

 

 

 


—Box Parts— 

Box Shape – Square Prism 

1 Top, 1 Bottom 

depth (c) = 15.16 in. (385 mm) 

width (b) = 13.5 in. (343 mm) 

thickness = 1 in. (25.4mm) 

1 Front, 1 Back 

height (a) = 11.5 in. (292 mm) 

width (d) = 11.5 in. (292 mm) 

c  

thickness = 1 in. (25.4mm) 

2 Sides 

 

Front 

& Back 

 

 

 

 

 

 

 

Sides 

height (a) = 11.5 in. (292 mm) 

depth (c) = 15.16 in. (385 mm) 

thickness = 1 in. (25.4mm) 

 

— 

Driver Mounting 

— 

Mounting: Front 

 

 

— 

Vent Parts 

— 

1 Top, 1 Bottom 

width (e) = 4 in. (102 mm) 

length (h) = 10.95 in. (278 mm) 

thickness = 0.75 in. (19 mm) 

h  

2 Sides 

 

 

height (g) = 2.5 in. (64 mm) 

length (h) = 10.95 in. (278 mm) 

thickness = 0.75 in. (19 mm) 

Summary of Contents for HCCA102

Page 1: ...Subwoofer MODEL HCCA102 HCCA104 HCCA122 HCCA124 HCCA152 HCCA154 OWNER S MANUAL...

Page 2: ...gh temperature possibilities of this woofer it is recommended that when the woofer is installed it be positioned so that the cone either faces upward or downward only FINDING SPEAKER MOUNTING LOCATION...

Page 3: ...sinking shorting rings to reduce inductive heating 13 Cast aluminum rear pole piece heat sink with fins and vent holes Part of the enhanced voice coil cooling system forced convection aluminum heat s...

Page 4: ...ORION HCCA 12 4 OHM Re Cone Kit HCCA152ck ORION HCCA 15 2 OHM Re Cone Kit HCCA154ck ORION HCCA 15 4 OHM Re Cone Kit WIRING CONFIGURATIONS The following illustrations provide guidelines on properly co...

Page 5: ...load to the amplifier Figure 2 Figura 2 Abbildung 2 1 Connect the woofer in series by connecting the negative of one terminal to the positive terminal of the other coil 2 Wire the positive terminal o...

Page 6: ...ad to the amplifier Figure 3 Figura 3 Abbildung 3 1 Connect the speaker in parallel by connecting the two positive terminals together and the two negative terminals together 2 Wire the positive termin...

Page 7: ...to the amplifier Figure 4 Figura 4 Abbildung 4 1 Connect the speaker in parallel by connecting the two positive terminals together and the two negative terminals together 2 Wire both positive terminal...

Page 8: ...ults in a 1 ohm load to the amplifier Figure 5 Figura 5 Abbildung 5 1 Connect the speaker in parallel by connecting the four positive terminals together and the four negative terminals together 2 Wire...

Page 9: ...e coil woofers with voice coils in series and then parallel the two series woofers results in a 2 ohm load to the amplifier Figure 6 Figura 6 Abbildung 6 1 Connect each woofer in series by connecting...

Page 10: ...ice coil woofer with voice coils of each woofer wired in series and then parallel the three woofers for a resulting 2 67 ohms load to the amplifier Figure 7 Figura 7 Abbildung 7 1 Connect each woofer...

Page 11: ...oil woofers should be wired with the voice coils on each woofer in series and then parallel the four woofers for a resulting 2 ohm load to the amplifier Figure 8 Figura 8 Abbildung 8 1 Connect each wo...

Page 12: ...oil woofers should be wired with the voice coils on each woofer in series and then parallel the four woofers for a resulting 1 ohm load to the amplifier Figure 9 Figura 9 Abbildung 9 1 Connect each wo...

Page 13: ...he speaker s voice coils to the first amplifier by connecting the positive terminal and the negative terminal from the speaker to the respective positive terminal and the negative terminal from the fi...

Page 14: ...he speaker s voice coils to the first amplifier by connecting the positive terminal and the negative terminal from the speaker to the respective positive terminal and the negative terminal from the fi...

Page 15: ...0 4000 Mms total moving mass grams 250 225 425 MS MECHANICALCOMPLIANCE MM 0 000056 0 000057 0 000057 Bl motor strength Tesla M 23 3 29 86 26 27 Sd effective radiating area sq cm 333 29 333 29 559 9 Sd...

Page 16: ...0 Mms total moving mass grams 386 500 460 MS MECHANICALCOMPLIANCE MM 0 00006 0 00005 0 000061 Bl motor strength Tesla M 33 2 25 34 32 21 Sd effective radiating area sq cm 559 9 962 11 962 11 Sd effect...

Page 17: ...for vented box designs Electrical Parameters were calculated in series ENCLOSURE DESIGN This section gives the basic description for a sealed enclosure Orion HCCA woofers are designed for sealed enclo...

Page 18: ...aster and more accurate bass A vented enclosure will offer greater efficiency and stronger low bass output compared to a sealed design A vented enclosure uses the back wave sound from the back side of...

Page 19: ...cu ft V total 1 cu ft Qtc 0 537 QL 20 F3 67 85 Hz Fill none External Dimensions A 14 in 356 mm B 14 in 356 mm C 14 in 356 mm Internal Dimensions A 12 in 305 mm A B 12 in 305 mm C 12 in 305 mm C Wall T...

Page 20: ...75 in 95 mm Wv 3 75 in 95 mm Lv 11 67 in 296 mm External Dimensions A 16 in 406 mm B 20 in 508 mm C 16 in 406 mm Internal Dimensions A 14 in A B 18 in 457 mm C 14 in 356 mm C Wall Thickness Front 1 i...

Page 21: ...in 292 mm C 13 16 in 334 mm C Wall Thickness Front 1 in 25 4mm B Sides 1 in 25 4mm Top c Bottom b d Box Parts Box Shape Square Prism 1 Top 1 Bottom depth c 15 16 in 385 mm width b 13 5 in 343 mm thick...

Page 22: ...No of Vents 1 Vent shape rectangle Vent ends one flush Hv 4 5 in 114 mm Wv 4 5 in 114 mm Lv 9 45 in 240 mm External Dimensions A 15 in 381 mm B 15 in 381 mm C 17 41 in 442 mm Internal Dimensions A 13...

Page 23: ...u ft Qtc 0 952 QL 12 95 F3 32 93 Hz Fill none External Dimensions A 17 71 in 450 mm B 27 42 in 697 mm C 11 71 in 297 mm Internal Dimensions A 15 71 in 399 mm A B 25 42 in 645 7 mm C 9 709 in 247 mm C...

Page 24: ...nts No of Vents 1 Vent shape rectangle Vent ends one flush Hv 5 in 127 mm Wv 5 in 127 mm Lv 14 54 in 369 mm External Dimensions A 18 in 457 mm B 18 in 457 mm C 22 78 in 579 mm Internal Dimensions A 16...

Page 25: ...406 mm C 16 36 in 416 mm C Wall Thickness Front 1 in 25 4 mm B Sides 1 in 25 4 mm Top c Bottom b d Box Parts Box Shape Square Prism 1 Top 1 Bottom depth c 18 36 in 466 mm width b 22 in 559 mm thicknes...

Page 26: ...ts No of Vents 1 Vent shape rectangle Vent ends one flush Hv 6 in 152 mm Wv 6 in 152 mm Lv 9 37 in 238 mm External Dimensions A 18 in 457 mm B 18 in 457 mm C 18 89 in 480 mm Internal Dimensions A 16 i...

Page 27: ...3 64 cu ft Qtc 0 587 QL 5 F3 45 39 Hz Fill none External Dimensions A 19 5 in 495 mm B 20 in 508 mm C 22 in 559 mm Internal Dimensions A 17 5 in 445 mm A B 18 in 457 mm C 20 in 508 mm C Wall Thickness...

Page 28: ...ents 1 Vent shape rectangle Vent ends one flush Hv 7 in 178 mm Wv 7 in 178 mm Lv 14 07 in 357 mm External Dimensions A 22 95 in 583 mm B 35 9 in 912 mm C 14 95 in 378 mm Internal Dimensions A 20 95 in...

Page 29: ...60 mm C 18 66 in 474 mm C Wall Thickness Front 1 in 25 4 mm B Sides 1 in 25 4 mm Top c Bottom b d Front a Back e c Sides Box Parts Box Shape Square Prism 1 Top 1 Bottom depth c 20 66 in 525 mm width b...

Page 30: ...pe rectangle Vent ends one flush Hv 10 in 254 mm Wv 10 in 254 mm Lv 14 34 in 364 mm External Dimensions A 22 23 in 565 mm B 34 74 in 882 mm C 14 51 in 369 mm Internal Dimensions A 20 23 in 514 mm A B...