HCCA122 & 124 Vented 2000+ Watts Input
Box Properties
—
Description
—
Type: Vented Box
Shape: Prism, Square
—
Box Parameters
— Vb
=
1.5 cu.ft
V(total) =
2.65 cu.ft
Fb
=
40 Hz
QL
=
5.256
F3
=
32.98 Hz
Fill
=
none
—
Vents
—
No. of Vents
= 1
Vent shape
= rectangle
Vent ends
= one flush
Hv
= 14 in. (356 mm)
Wv
= 2 in. (51 mm)
Lv
= 30.33 in. (770 mm)
—
External Dimensions
—
A = 16 in. (406 mm)
B = 22 in. (559 mm)
C = 18.36 in. (466 mm)
—
Internal Dimensions
—
A = 14 in. (356 mm)
A
B = 20 in. (406 mm)
C = 16.36 in. (416 mm)
C
—
Wall Thickness
—
Front = 1 in. (25.4 mm)
B
Sides = 1 in. (25.4 mm)
Top &
c
Bottom
b
d
—Box Parts—
Box Shape – Square Prism
1 Top, 1 Bottom
depth (c) = 18.36 in. (466 mm)
width (b) = 22 in. (559 mm)
thickness = 1 in. (25.4 mm)
1 Front, 1 Back
height (a) = 14 in. (356 mm)
width (d) = 20 in. (406 mm)
c
thickness = 1 in. (25.4 mm)
2 Sides
Front
a
& Back
e
Sides
height (a) = 14 in. (356 mm)
depth (c) = 18.36 in. (466 mm)
thickness = 1 in. (25.4 mm)
—
Driver Mounting
—
Mounting: Front
—
Vent Parts
—
h
1 Top, 1 Bottom
h
width (e) = 3.5 in. (89 mm)
length (h) = 30.33 in. (770 mm)
g
thickness = 0.75 in. (19 mm)
2 Sides
height (g) = 14 in. (356 mm)
length (h) = 30.33 in. (770 mm)
thickness = 0.75 in. (19 mm)