IGS-9084GP-FB2 Series User Manual
ORing Industrial Networking Corp
74
Private VLAN ID
Indicates the ID of this particular private VLAN.
MAC Address
The MAC address for the entry.
Port Members
A row of check boxes for each port is displayed for each private
VLAN ID. You can check the box to include a port in a private
VLAN. To remove or exclude the port from the private VLAN,
make sure the box is unchecked. By default, no ports are
members, and all boxes are unchecked.
Adding a New Static
Entry
Click
Add new Private VLAN
to add a new private VLAN ID. An
empty row is added to the table, and the private VLAN can be
configured as needed. The allowed range for a private VLAN ID is
the same as the switch port number range. Any values outside
this range are not accepted, and a warning message appears.
Click OK to discard the incorrect entry, or click Cancel to return to
the editing and make a correction.
The private VLAN is enabled when you click Save.
The
Delete
button can be used to undo the addition of new
private VLANs.
A private VLAN is defined as a pairing of a primary VLAN with a secondary VLAN. A
promiscuous port is a port that can communicate with all other private VLAN port types via the
primary VLAN and any associated secondary VLANs, whereas isolated ports can
communicate only with a promiscuous port.
Label
Description
Port Members
A check box is provided for each port of a private VLAN.
When checked, port isolation is enabled for that port.
When unchecked, port isolation is disabled for that port.
By default, port isolation is disabled for all ports.