![ORiNG IGS-9084GP-FB2-MM User Manual Download Page 19](http://html1.mh-extra.com/html/oring/igs-9084gp-fb2-mm/igs-9084gp-fb2-mm_user-manual_1651952019.webp)
IGS-9084GP-FB2 Series User Manual
ORing Industrial Networking Corp
18
When the switch breaks down, incoming traffic will travel through the bypass port board and
onto another active switch.
Note that the fiber port will still work if it is not connected to any monitor port. However, the fiber
port will not have bypass ability when the device is down.
3.4.2 O-Ring/O-Chain
O-Ring
You can connect three or more switches to form a ring topology to gain network redundancy
capabilities through the following steps.
1. Connect each switch to form a daisy chain using an Ethernet cable.
2. Set one of the connected switches to be the master and make sure the port setting of each
connected switch on the management page corresponds to the physical ports connected. For
information about the port setting, please refer to 4.1.2 Configurations.
3. Connect the last switch to the first switch to form a ring topology.