IDS-5612 Series User’s Manual
61
ORing Industrial Networking Corp.
5.4 Configuration by Console Command
You can use the Serial Console to configure the device. First you should connect the
device port with Terminal COM. Input
“+++
” command, Enter the device console command.
Input the
“exit”
command, Exit the device console command and Return to data mode.
Label
Description
Help
Display all command information.
IP
Set the device IP address.
?IP
Query IP address, return IP address value.
Mask [subnet
mask] -
Set device subnet mask.
?mask
Query subnet mask, return subnet Mask value.
Gateway
[gateway
address] -
Set the device default gateway address.
?gateway
Query Gateway address, return the gateway address value.
DHCP [0/1]
Enable/disable DHCP Service.
0=disable 1=enable
?DHCP
Query DHCP client setting.
SioMode [mode]
Set serial port socket mode
0=TCP server, 1=TCP client, 2=UDP, 3=VCOM
?SioMode
Query serial port socket mode.
0=TCP server, 1=TCP client, 2=UDP, 3=VCOM
SioPort [port]
Set serial socket port.
?SioPort
Query serial socket port, return port value.
SioType [type]
Set serial port interface type
0=RS232 None, 1=RS232 RTS/CTS, 2=RS232 XON/XOFF 3=RS232 RTS/CTS
XON/XF
?siotype
Query serial port interface type, return it value.
SioBaud [rate]
Set serial port baud rate
0=300 bps, 1=600 bps.
?SioBaud
Query serial port baud rate, return Baud value.
SioParity [parity]
Set serial port parity
0=none, 1=even, 2=odd, 3=mark, 4=space
?SioParity
Query serial port parity, return value. 0=none, 1=even, 2=odd,
3=mark, 4=space
SioBits [data bits]
Set serial port data bits
0=5, 1=6, 2=7, 3=8
?SioBits
Query serial port data bits, get it.
SioStops [stop
bits]
Set serial port stop bits
0=1, 1=2
?Siostops
Query serial port stop bits, return the Siostops value.
DeviceId [Device
Id]
Set device ID.
?DeviceID
Query device ID, return the device ID.
Password
Set setup password