IDS-5011F Series User’s Manual
27
ORing Industrial Networking Corp.
The following table describes the labels in this screen.
Label
Description
Map Virtual COM
Select a Virtual COM Name to map on.
Max Connection
The number of Max connection can support simultaneous connections are 5, default
values is 1.
Idle Timeout
When serial port stops data transmission for a defined period of time (Idle Timeout), the
connection will be closed and the port will be freed and try to connect with other hosts. 0
indicate disable this function. Factory default value is 0. If Multilink is configured, only
the first host connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check package in each defined time interval (Alive
Check) to remote host to check the TCP connection. If the TCP connection is not alive,
the connection will be closed and the port will be freed. 0 indicate disable this function.
Factory default is 0.
Table 5-8 Virtual COM
*
Not allowed to mapping Virtual COM from web
Service Mode – TCP Server Mode
In TCP Server Mode, DS is configured with a unique Port combination on a TCP/IP
network. In this case, DS waits passively to be contacted by the device. After a
connection is established, it can then proceed with data transmission. TCP Server
mode also supports up to 5 simultaneous connections, so that multiple device can
receive data from the same serial device at the same time.