44
GB
1.
Please use driver with special
head for removed and install nozzle as (Figure-10)
2.
Please remove nozzle (Figure -11)
from burner with special nozzle driver
and install new nozzle (Figure -12)
REDUCED GAS FLOW RATE SETTING FOR HOB TAPS
1.
Ignite the burner that is to be adjustment and turn the knob to the
reduced position.
2.
Remove the knob from the gas tap.
3.
Use an appropriately sized screwdriver to adjust the low rate adjustment screw.
For LPG (Butane - Propane) turn the screw clockwise. For the naturel
gas, you should turn the screw counter- clockwise once.
“The normal length of a straight lame in the reduced position should be 6-7 mm.
4.
If the lame is higher then the desired position, turn the screw clock
-
wise. If it is smaller turn anticolockwise.
5.
For the last control, bring the burner both to higt-lame and reduced
positions and check whether the lame is on or off.
Depending on the type of gas tap used in your appliance the adjustmenr
screw position may vary.
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14