36
III.
Technical Parameter
Model
EL 011941
THP04N
Performance Condition: Air 26
℃
, Water 26
℃
Heating Capacity (KW)
3,6
C.O.P.
5,2
Performance Condition: Air 15
℃
, Water 26
℃
Heating Capacity (KW)
2,7
C.O.P.
4,1
Advised Water Flux m³/h
2-3
Power Supply
230V/1Ph/50Hz
Rated Power kW
0,66
Rated current A
3,0
Max input current A
5,5
Water Pipe In-out Spec
mm
50
Net Weight / Gross Weight Kg
31/36
Notice:
1.
This product can work well under air temp 0
℃~
+43
℃
, efficiency will
not be guaranteed out of this range. Please take into consideration that the pool
heater performance and parameters are different under various conditions.
2.
Related parameters are subject to adjustment periodically for technical
improvement without further notice. For details please refer to nameplate.