Maintenance
28
7-3
Checking the belt (Parallel motor mounting type)
Detach the pulley cover, and check the belt condition according to the items in the table below.
As the result of checking, replace the belt if abnormality is detected. Refer to p.29 for how to replace the belt.
Inspection interval
Every 500 km (310 mi) in mileage
Inspection item
•
No crack on the belt rubber
•
No tooth chip on the belt
•
No abnormal wear on the tooth cloth of the belt
Checking method
1. Remove the pulley cover fixing screws, and detach the pulley cover.
Pulley cover fixing screws
(M3)
Pulley cover
Pulley cover fixing screws
(M3)
Pulley cover
EZSM3
,
EZSM4
EZSM6
2. Check the the belt condition. And check the belt does not detach or protrude from the pulley.
3. Attach the pulley cover, and tighten the screws.
Tightening torque: 1 N•m (142 oz-in)