![Orientalmotor EZS Series Operating Manual Download Page 24](http://html1.mh-extra.com/html/orientalmotor/ezs-series/ezs-series_operating-manual_1651249024.webp)
Connection
24
2) Grounding the grounding wire of the motorized linear slide [AC power input type only]
Connect the grounding wire of the "cable for motor" to the Protective Earth Terminal of the driver.
Cable for motor
Connect the grounding wire
to the driver Protective Earth
Terminal
Grounding
Protective Earth
Terminal
3) Grounding the Protective Earth Terminal of the motorized linear slide
Be sure to ground the Protective Earth Terminal of the motorized
linear slide.
•
Grounding wire: AWG18 (0.75 mm
2
) or more
•
Screw size of Protective Earth Terminal: M4
•
Tightening torque: 1.2 N•m (170 oz-in)
Grounding
Protective Earth Terminal
Motorized linear slide equipped with the
AR
Series
If the DC power input type product is used at 48 VDC or the AC
power input type is used, be sure to ground the Protective Earth
Terminal of the motorized linear slide.
•
Grounding wire: AWG18 (0.75 mm
2
) or more
•
Screw size of Protective Earth Terminal: M4
•
Tightening torque: 1.2 N•m (170 oz-in)
Grounding
Protective Earth Terminal