Convenient functions
−26−
8.3 Parameter list
Operation mode: Parameter mode
Item
Display
Description
Setting range
Factory
setting
Speed reduction ratio
Gr-r
Sets the speed reduction ratio
relative to the rotation speed of the
motor output shaft. Displays the
speed calculated based on the speed
reduction ratio on the monitor mode.
If the speed reduction ratio for the
conveyor is calculated and input, the
conveyor transfer speed can also be
displayed.
1.00 to 9999
1.00
Speed increasing ratio
Sp-r
When increasing the motor rotation
speed using the external mechanism
and others, the converted speed can
be displayed.
1.00 to 2.00
1.00
Panel initial view
PDSp
After the power is turned on, the item
displayed on the monitor mode can
be changed.
SpD
Rotation speed (r/min)
SpD
trQ
Load factor (%)
D-no
Operation data No.
Prevention of operation at
power-on alarm
opAL
Sets whether to enable or disable the
"prevention of operation at power-on
alarm."
oFF
Disable
on
on
Enable
Reset method selection for
the prevention of operation
at power-on alarm
oArS
Selects how to reset the prevention
of operation at power-on alarm.
DoFF
Resets by turning the FWD
input or REV input OFF, or by
setting the operation switch to
the STAND-BY side.
DoFF
ArSt
Resets using the
ALARMRESET input or the
alarm reset on the monitor
mode.
Analog acceleration/
deceleration time
tAtD
Changes the setting method of
acceleration/deceleration time.
An
Sets using the acceleration/
deceleration time potentiometer.
(analog)
An
D G
Sets using the operation data.
(digital)
Speed upper
and lower
limit
SPL~
n
Speed
upper
limit
H
Sets the upper limit of the rotation
speed.
50 to 4000
4000
Speed
lower
limit
Lo
Sets the lower limit of the rotation
speed.
50
Slight position-keeping
selection
HoLD
The load position can be kept at
motor standstill.
oFF
Disable
oFF
on
Enable
External operation signal
input
oEn
The operation method can be
selected between the front panel and
external input signals.
When operating or stopping the motor
using the external input signals, the
functions of the operation switch,
rotation direction switch, and setting
dial can be set to disable.
oFF
Operation/standstill using
front panel
oFF
on
Operation/standstill using
external signals
(Front panel operation: Enable)
rE
Operation/standstill using
external signals
(Front panel operation: Disable)
IN0 input function selection
n-0
Assigns the input signals to the
external input terminals.
----
Not used
F_
wd
FWD
rEu
REV
~
n0
M0
~
n1
M1
ArSt
ALARM-RESET
E-Er
EXT-ERROR
H-Fr
H-FREE
F_
wd
IN1 input function selection
n-1
rEu
IN2 input function selection
n-2
~
n0
IN3 input function selection
n-3
~
n1
IN4 input function selection
n-4
ArSt
Summary of Contents for BMU5200A Series