background image

4

Unauthorized reproduction or copying of all or part of this manual is 

prohibited.

Oriental Motor shall not be liable whatsoever for any problems relating 

to industrial property rights arising from use of any information, circuit, 

equipment or device provided or referenced in this manual.

Characteristics, specifications and dimensions are subject to change without 

notice.

 is a registered trademark or trademark of Oriental Motor 

Co.,Ltd., in Japan and other countries.

© Copyright ORIENTAL MOTOR CO., LTD. 2014

Technical Support  Tel:(800)468-3982

8:30 

A.M.

 to 5:00 

P.M.

, P.S.T. (M-F)

7:30 

A.M.

 to 5:00 

P.M.

, C.S.T. (M-F)

www.orientalmotor.com

Schiessstraße 74, 40549 Düsseldorf, Germany

Technical Support  Tel:00 800/22 55 66 22

www.orientalmotor.de

Tel:01256-347090

www.oriental-motor.co.uk

Tel:01 47 86 97 50

www.orientalmotor.fr

Tel:02-93906346

www.orientalmotor.it

Tel:+55-11-3266-6018

www.orientalmotor.com.br

• Please contact your nearest Oriental Motor office for further information.

4-8-1Higashiueno,Taito-ku,Tokyo 110-8536 

Japan

Tel:03-6744-0361

www.orientalmotor.co.jp

Tel:0800-060708

www.orientalmotor.com.tw

Singapore

Tel:1800-8420280

www.orientalmotor.com.sg

Tel:1800-806161

www.orientalmotor.com.my

Korea

Tel:080-777-2042

www.inaom.co.kr

Tel:1800-888-881

www.orientalmotor.co.th

Tel:400-820-6516

www.orientalmotor.com.cn

Tel:+91-80-41125586

www.orientalmotor.co.in

Hong Kong Branch

Tel:+852-2427-9800

Burnout protection for overload/locked-rotor state

Note

In order to prevent the motor from burning out for when the 

output shaft is locked or in the case of an overload state, use an 

electromagnetic switch.

When connecting to an inverter, use the electronic thermal relay 

function of the inverter.

„

„

When connecting to the power supply

Always connect an electromagnetic switch. 

Connect the electromagnetic switch according to the operating manual of the 

electromagnetic switch.

Set the motor rated current for the thermal relay. 

The motor rated current is described on the motor nameplate.

For electromagnetic switches, use the products as shown in the chart, or an 

equivalent.

[ Fuji Electric FA Components & Systems Co., Ltd. ]

For motor output power 60 W  Model: SC11AAN-

10TF

For motor output power 100 W  Model: SC11AAN-

10TH

(

: Coil code)

Coil code

50 Hz

60 Hz

2

200 V

200-220 V

M

200-220 V

220-240 V

P

220-240 V

240-260 V

Use the product which satisfies the motor rated voltage by selecting the coil 

code.

[ Mitsubishi Electric Corporation ]

For motor output power 60 W 

Model: MSO-T10 0.35A 200V AC200V

For motor output power 100 W  Model: MSO-T10 0.5A 200V  AC200V

„

„

When connecting to the inverter

Be sure to set the electronic thermal relay according to the operating manual of 

the inverter. Unless the electronic thermal relay is set, a burnout may result.

When using the motor with an inverter 

When the motor is used with connecting an inverter, perform the following 

settings to the inverter.

When driving the inverter, use it at the setting frequency 120 Hz or lower.

„

„

Setting for motor

Electronic thermal relay function

Set the rated current listed on the motor 

nameplate based on the base frequency 

and the voltage applied to the motor.

Applicable motor setting

Constant-torque motor or inverter motor

Motor capacity

Motor rated output power  

If the setting value in the inverter does not 

exist, set the closest value.

Number of motor poles

4 poles

„

„

Notes about when using the motor with an inverter

The inverter which input voltage exceeds 240 VAC cannot be used.

The insulation of the motor winding may deteriorate, causing damage to the 

motor.

Time rating

Continuous operation is possible (continuous rating).

Troubleshooting

When the motor cannot be operated correctly, refer to the contents provided in 

this section and take appropriate action. If the problem persists, contact your 

nearest office.

Phenomena

Check items

Motor does not rotate.
Motor sometimes 

rotates and stops.

Check the power supply voltage.

Connect the power supply and the motor correctly.

If terminal blocks or crimp terminals are used, check 

them for poor connection.

Keep the load at or below the allowable value.

The motor rotates in 

the direction opposite 

to the specified 

direction.

The connection varies depending on the gear ratio of 

the gearhead.

The rotation direction is as viewed from the output 

shaft end. Check the reference direction.

Motor temperature 

abnormally high.

[Motor case 

temperature exceeds 

90 °C (194 °F)]

Check the power supply voltage.

Review the ventilation condition.

Noisy operation.

Check whether the combination of the motor and 

gearhead is correct. (Refer to p.1 for the combinations)

Standard and CE Marking

This product is recognized by UL under the UL and CSA standards.  

Also, it conforms to the China Compulsory Certification System (CCC System).  

The motor model name is the recognized product name.

The motor is affixed the CE Marking under the Low Voltage Directive.

„

„

UL Standards

*

, CSA Standards

*

, CCC System

*

Applications standards

Certification Body / File No.

UL 1004-1

UL /

UL File No.E62327

CSA C22.2 No.100
GB 12350

CQC

Thermal Class: 130 (B)

„

„

CE Marking

*

Applications standards

EN 60034-1, EN 60034-5, EN 60664-1

Installation conditions 

(For EN standard)

Terminal box type: Overvoltage category 

ІІ

, Pollution degree 3, Class 

І

 equipment

Lead wire type: Overvoltage category 

ІІ

, Pollution degree 2, Class 

І

 equipment

When the machinery to which the motor is mounted requires overvoltage 

category 

ІІІ

 specifications, install the motor in a cabinet that connect to power 

supply via an isolation transformer.

*

Temperature rise tests required by the above standards are performed in a 

state that has been attached a heat radiation plate instead of a gearhead.

The size and material for the heat radiation plates are as follows.

Size: 200×200 mm (7.87×7.87 in.)

Thickness: 5 mm (0.20 in.)      Material: Aluminum alloy

Summary of Contents for KIIS Series

Page 1: ...y result in electric shock injury or damage to equipment Do not touch the motor during operation or immediately after stopping The surface is hot and may cause a skin burn s Do not lift the motor by holding the motor output shaft or motor lead wires Doing so may result in injury Keep the area around the motor free of combustible materials Failure to do so may result in fire or a skin burn s Do not...

Page 2: ...or case side Installing a gearhead to a motor Using the pilot sections of the motor and gearhead as guides slowly rotate it clockwise counterclockwise to prevent the pinion of the motor output shaft from contacting the side panel or gear of the gearhead Also confirm that no gaps remain between the motor and gearhead An O ring is attached to the flange of the motor Do not pinch the O ring when asse...

Page 3: ...asket with facing the cutout to the motor side opposite the output shaft side as shown in the figure Assemble not to enter any foreign object between the terminal box and terminal block base Lead wire type z z Connecting Protective Earth Terminal Ground the motor using the Protective Earth Terminal on the motor Applicable crimp terminal Insulated round crimp terminal Terminal screw size M4 Tighten...

Page 4: ...n the motor is used with connecting an inverter perform the following settings to the inverter When driving the inverter use it at the setting frequency 120 Hz or lower Setting for motor Electronic thermal relay function Set the rated current listed on the motor nameplate based on the base frequency and the voltage applied to the motor Applicable motor setting Constant torque motor or inverter mot...