![OREX AA095042-00 Service Manual Download Page 68](http://html1.mh-extra.com/html/orex/aa095042-00/aa095042-00_service-manual_1650368068.webp)
4. Install the new Sensor, by the marking of the old one, and secure
with the Allen screws.
5. Connect the Sensor Cable to the connector on the connector
panel.
5.14
Replacing the Right Origin
Sensor
1. Remove the cover. Refer to Section 5.1.1, page 37.
2. Move the Optical Head a few centimeters to the left.
3. Mark the position of the sensor on the sensor bracket.
4. Disconnect the cable from the connector on the Sensor Bracket,
open two 2.0mm Allen screws, and remove the Sensor.
5. Install the new Sensor, by placing it on the marking, and secure
with the screws.
6. Connect the Sensor Cable to the connector.
Service Operation
Page
63 of 63
Summary of Contents for AA095042-00
Page 9: ...3 2 System Block Diagram Component Description Page 4 of 4...
Page 10: ...3 3 USB Board 3 3 1 Location 3 3 2 Component Component Description Page 5 of 5...
Page 12: ...3 4 Motion Board 3 4 1 Location 3 4 2 Component Component Description Page 7 of 7...
Page 15: ...3 5 Sensor Board 3 5 1 Location 1 3 5 2 Component 2 Component Description Page 10 of 10...
Page 23: ...3 10 Step Motor Slide 3 10 1 Location 3 10 2 Component Component Description Page 18 of 18...
Page 25: ...3 11 Step Motor Carriage 3 11 1 Location 3 11 2 Component Component Description Page 20 of 20...
Page 29: ...3 13 Erase Lamps Sensor 3 13 1 Location 3 13 2 Component Component Description Page 24 of 24...
Page 35: ...3 18 Erase Lamps 3 18 1 Location 3 18 2 Component Component Description Page 30 of 30...
Page 37: ...3 19 Inverters Assembly 3 19 1 Location 3 19 2 Component Component Description Page 32 of 32...
Page 43: ...5 1 2 Service Panel 1 Open the back panel Philips screws Service Operation Page 38 of 38...