The air purifier and the outer Pre-/Activated Carbon Filter attached to the HEPA Filter 
should be cleaned at least once every month. More frequent cleaning may be required 
depending on environmental conditions. 

FILTERS 

Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt. 

        

        

Combination filter

Pre-  HEPA

   

NOTE

:  

-  Only  the 

Extra  Pre-filter

  is  washable.  Make  sure  the  pre-filter  is  dry  before 

attaching the pre-filter to the combination filter. 
- The Combination Filter is one filter system. The multiple layers include the Pre-filter, 
activated Carbon Filter and the HEPA Filter. 
 

UV LAMP RPLACEMENT 

1.

 

Open the UV lamp cover by using a screwdriver. 

2.

 

Carefully remove the UV lamp from the holder and unplug the connector. 

3.

 

Connect the new UV lamp to the connector and carefully fit the lamp back into the 
holder. 

 

Note

: Do not look at the UV lamp directly while it is on. 

 
 
 
 
 
 

 
 

CLEANING & MAINTAINING

 

THE COMBINATION FILTER

 

Summary of Contents for CF-8410

Page 1: ...1 USER MANUAL Air Purifier With Pre filter HEPA Activated Carbon UVC CF 8410 ...

Page 2: ...electrician Do not attempt to defeat this safety feature To avoid fire or shock hazard plug the appliance directly into a correct AC electrical outlet Keep the cord out of heavy traffic areas To avoid fire hazard NEVER put the cord under rugs or near radiators stoves or heaters To protect against electrical hazards DO NOT immerse in water or other liquids and do not use near water As children are ...

Page 3: ... or sofa as this could cause the unit to tip over blocking the air intake or outlet opening DO NOT attempt to repair or adjust any electrical or mechanical functions onthis unit Doing so will void your warranty The inside of the unit contains no user serviceable parts All servicing should be performed by qualified personnelonly WARNING To reduce the risk of fire or electric shock do not use this f...

Page 4: ...nces the killing of germs PRE FILTER Captures initial dust and allergen particles ACTIVATED CARBON FILTER Absorb formaldehyde benzene and other noxious gases HEPA FILTER Captures dust smoke pollen and other allergens UV C LIGHT Destroys micro organisms such as germs viruses bacteria and fungi such as mold toxins PRODUCT COMPONENTS UV C lamp Front cover Air outlet 3 in 1 filter Pre filter Activated...

Page 5: ... then remove and discard the bags Replace the filters 6 Plug the power cord into a right voltage AC outlet IMPORTANT When moving the air purifier always lift unit by the carrying handle located at the back OPERATING THE AIR PURIFIER 1 POWER UV C BUTTON Press this button to turn on or switch off the unit and UV light 2 SPEED BUTTON The fan speed of the unit can be adjusted while the unit is in oper...

Page 6: ...RS FILTER REPLACE INDICATOR When the POWER light flashes continuously the filter needs to be replaced Replace the filter according to the directions then hold the POWER UV C button for 5 seconds to restart the system The light will stop flickering Combination Filter will last approximately 6 months 1 Open the front cover from the top 2 Remove the combination filter by pulling the two strips 3 Inse...

Page 7: ...e filter is washable Make sure the pre filter is dry before attaching the pre filter to the combination filter The Combination Filter is one filter system The multiple layers include the Pre filter activated Carbon Filter and the HEPA Filter UV LAMP RPLACEMENT 1 Open the UV lamp cover by using a screwdriver 2 Carefully remove the UV lamp from the holder and unplug theconnector 3 Connect the new UV...

Page 8: ...ng out any of the following service checks unplug the unit from the power outlet Insufficient air flow Check that the filters are clean Check for any obstructions in the air inlet and outlet Unit will not start Check the power supply and electric fuses Check that the Front Cover is latched firmly in place Check that the Filter is firmly in place Excessive noise Check for any foreign objects touchi...

Page 9: ...lar installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on...

Reviews: