background image

6

fig. 25

To reassemble, check O-ring on tube, and replace if damaged.
Vacuum will not operate properly without the tube O-ring. Slide
O-ring to approximately 2" from base of tube. Replace tube by
first lining up slot at base of tube with inner tab inside fan
housing. Then reinsert tube and push down until the tube is
seated. Make sure O-ring is in place against fan housing
opening. Replace and tighten collar until collar locking tabs are
locked in place. 

fig. 28

Make sure collar is not cross threaded on housing. Reattach
bag spring 

(fig. 24).

fig. 29

Many times blockage occurs due to a full dust bag causing dirt to
back down the air flow system. When that happens, the
blockage will be at the top of the system, starting in the area
where the dust bag connects to the connector assembly.

NOTE: 

If the above actions do not correct the problem, contact an

Oreck Authorized Service Center or call the customer service center
at: 0845 603 0153.

Summary of Contents for XL SIMLY AMAZING XL5-105HH

Page 1: ...SAVE THIS BOOKLET XL5 105HH XL5 205HH HIGH SPEED UPRIGHT VACUUM CLEANER WITH CLEANING SYSTEM S I M P L Y A M A Z I N G Includes Safety Warnings Warranty Operating Instructions Trouble Diagnosis Access...

Page 2: ...ring Anneau torique Anillo t rico 29 Connector Deflector Opening Ouverture du connecteur d flecteur Abertura del deflector de la conexi n 26 27 Fan Housing Bo tier du ventilateur Bastidor del ventilad...

Page 3: ...ys be followed including the following READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER WARNING To reduce the risk of fire electric shock or injury IMPORTANT SAFETY INSTRUCTIONS Do not leave app...

Page 4: ...9560 gives you the following warranty for this product only if it was originally purchased for residential use not resale from Oreck or an Oreck Authorized Retail Dealer Oreck will repair or replace f...

Page 5: ...revolving brush and is very important for the effective operation of the cleaner If the belt becomes stretched or cut it will cause the revolving brush to stop completely or slow down See instruction...

Page 6: ...groove at the bottom of the housing fig 12 Replace the hold down screw and tighten To Adjust or Replace Brush WARNING Unplug cord from electrical outlet before servicing fig 16 To determine if the br...

Page 7: ...using opening Replace and tighten collar until collar locking tabs are locked in place fig 28 Make sure collar is not cross threaded on housing Reattach bag spring fig 24 fig 29 Many times blockage oc...

Page 8: ...oldings LLC All rights reserved All word marks logos product configurations and registered trademarks are owned and used under the authority of Oreck Holdings LLC Printed in America 75724 03 REV B 12...

Reviews: