![Oreck U3795HHS User Manual Download Page 9](http://html1.mh-extra.com/html/oreck/u3795hhs/u3795hhs_user-manual_1648680009.webp)
9
Service problems that appear to be major can often be solved easily. You can be your own
troubleshooter by reviewing this guide.
All other servicing should be done by an Oreck Approved Service Centre.
All accessories and replacement parts are sold separately. To order, call Customer Care on
0845 603 0153
or visit our website www.oreck.co.uk. Please have your model number
from the data label on the bottom of the unit.
Accessories
Item
Part Number
Crystal Aroma
®
Carpet and Room Freshener
CRYSTAL
Oreck Dry Carpet
®
Cleaning System
CARPETCSYS
Item
Part Number
Dust Bag, 8 Pack, Saniseal
®
Hypo-Allergenic
PK20008DW
Belts, 3 Pack
3BELTS
H
S
I
L
G
N
E
Parts
Replacement Parts
Trouble-
shooting
Problem
Check
What to do
Cleaner will not
run.
• Not plugged in properly.
• No electricity in wall
outlet.
socket.
• Check electrical source – fuse or circuit
breaker.
Cleaner does not
pick up.
• Filter Bag is full.
• Nozzle or intake
clogged.
• Belt is broken or
stretched.
• Brush is worn.
• Bag tube clogged.
• Bag pores are clogged
• Revolving brush not
even at each end.
• Clear obstruction. See “Stuffing or
Blockage” page 8.
• Replace belt.
• See “Adjusting or Replacing Brushroll”
page 7.
• Clear obstruction. See “Stuffing or
Blockage” page 8.
• Change bag.
• Check that the brushroll is aligned
correctly. See “Adjusting or Replacing
Brushroll” page 7.
Unit still does not
operate properly.
• Contact Oreck for service.
Service Kit
SERKIT35G
Dust Bags, 8 Pack, HEPA Odour Fighting
CCPK8OH
Fresh Air Scented Tablets
AIRTABS
• Replace Filter Bag. See “Replacing
Disposable Dust Bag” page 6.
Summary of Contents for U3795HHS
Page 11: ...11...