Remove the baseplate by removing 5 screws.
Remove the belt from the brushroll pulley. Then, remove the brushroll from the housing.
Remove the fascia by removing 2 screws.
Rotate fascia away from the power head and lift it away.
Pull burned out bulb from holder and replace with new bulb.
Reassemble the fascia.
Reassemble the brushroll and belt.
Reassemble the baseplate.
Replacing Light Bulbs
19
20
WARNING: Unplug cord from electrical outlet before servicing.
Your Oreck Vacuum has a brushroll that can be replaced after heavy use for improved performance.
Remove the baseplate by removing 5 screws. Then, remove the belt and brushroll from the housing.
Snap the new brushroll into place.
Reassemble the belt.
Reassemble the baseplate.
Adjusting or Replacing Brushroll