4. -  INSTALLATION 

 

4.1. -  UNPACKING 

 

Upon reception of the equipment, if package is seen as damaged, immediately check if device has been affected. 

When device is checked and damages are confirmed, immediately refer then to the technical service for a review and be sure that 

not any internal failure has happened. 

 

 

4.2. -  MOUNTING  

 

4.2.1.-  MOUNTING THE LAMP   

 

For assembly of the lamp, follow these instructions: 

 

1.  Assemble the support bar No.

7

 with the base foot No. 

12

, entering the electrical cord on his inside No. 

17

. Hold the tubing 

through the screw No. 

16

 

2.  Insert de fuse 250VF5A (No. 

10

) to activate emergency equipment

.

 

3.  Assemble the cupola No. 

3

 with the arm No. 

6

, hold the copula through the screws No. 

13

, and adjust these until you can 

move the copula with a gentle moving. 

 
 

 

 

 

 

 

4.2.2. - ELECTRICAL INSTALLATION  

 

Electrical installation of the room where you plan to use the equipment should be in accordance with the rules UNE (CIS), as well 

as the Low Voltage Regulation.  

The plug socket where the equipment is going to be connected, must be suitable for plugs according to standard rules UNE 20.315 

and / or DIN 49.441, with terminals of 4'8 mm and lateral earthing 

 

 

4.3. - TURNING ON THE LAMP 

 

1. 

Position the lamp in the most appropriate place, and immobilize, through brakes of the wheels No. 

8

2. 

Connect the lamp to the mains. A red light should appear on the keypad.  

3. 

Turn on the lamp, using the keypad No.

5

, and adjust the light intensity with the + and – buttons. 

(See Fig. 3)

 

4. 

To change the position of the lamp uses the handle No. 

1

. Do these gently avoiding brusque movements. 

5. 

In the event of having to move the lamp, never do it through the handle No. 

1

. Push it through the support bar No. 

7

 

 

 

Fig. 2b – Fork assembly

 

Fig. 2a – Base foot assembly

 

A

 – On / Off button 

B

 – On / Off Led indicator 

C

 – Luminous intensity adjustment buttons  

D

 – Luminous intensity Leds indicators.  

Fig. 3 – Keypad 

Summary of Contents for IG-65MB

Page 1: ...Mom 44 Edici n 1 Fecha 2017 01 10 Tecnolog a 2 Nave 7 08780 Pallej Barcelona Spain 34 93 334 01 12 FAX 34 93 440 25 64 comercial ordisi com www ordisi com...

Page 2: ...ibuidor ORDISI m s pr ximo o directamente a nuestra Central ORDISI S A Tecnolog a 2 08780 Pallej Barcelona Espa a Tel 34 93 334 01 12 Fax 34 93 440 25 64 e mail comercial ordisi com 2 RESPONSABILIADES...

Page 3: ...NE CEI as como con el Reglamento de Baja Tensi n La base enchufe en donde se conecte el equipo debe ser apta para clavijas seg n norma UNE 20315 y o DIN 49441 con bornes de 4 8 mm y toma de tierra lat...

Page 4: ...ue sta no penetre al interior de la c pula Para las manchas persistentes p e sangre desinfectantes etc se puede utilizar un poco de jab n neutro No utilizar bajo ning n concepto productos que contenga...

Page 5: ...Fuente de luz LED Vida LEDS 50 000 h Temperatura de color 4 500K 5 CRI 95 Potencia 28 W de la c pula 300 mm campo de trabajo d10 260 mm campo de trabajo d50 130 mm Profundidad de campo L1 L2 170 cm 8...

Page 6: ...ur L33 38 please contact your nearest ORDISI distributor or contact us to our head office directly ORDISI S A Tecnolog a 2 08780 Pallej Barcelona Espa a Tel 34 93 334 01 12 Fax 34 93 440 25 64 e mail...

Page 7: ...ion of the room where you plan to use the equipment should be in accordance with the rules UNE CIS as well as the Low Voltage Regulation The plug socket where the equipment is going to be connected mu...

Page 8: ...de of the equipment via the ventilation grille For Example blood disinfectants etc a little neutral soap can be used Do not use products containing acetone in any case Dry the lamp well before use If...

Page 9: ...10 Illumination intensity adjustment from 20 000 to 65 000 lux Light source LED Colour temperature 4 500 K 5 CRI 95 Power 28W Light head 300 mm Field diameter d10 260 mm Field diameter d50 130 mm Dep...

Page 10: ...P gina 10 de 11 9 PLANOS Y ESQUEMAS PLANS AND DRAWINGS Fig 6 Despiece de la c pula Exploded view of the cupola...

Page 11: ...P gina 11 de 11 Fig 7 Despiece de brazos y base rodable Exploded view of arms and base...

Reviews: