background image

8

4. Operating the unit

4.1 Operation with 3-position switch

If your unit is equipped with a perilex connector and 3-position switch, the ventilation 
positions can be set from the table below. If several switches or controls are used in 
your home, the last selected ventilation position always takes precedence.

Explanation of Ventilation settings 

Setting 1

Low

Absent setting

For use during absence during a long 
period

Setting 2

Medium

Present setting

For daily use with normal use within 
the home

Setting 3

High

High setting

For use during cooking, showering  
or parties

4.2 Operation using RF remote control

The balance ventilator can be operated using a wireless remote control (15 RF). The
remote control has 6 buttons, the functions of which are explained in the table below.

Explanation of remote control buttons

Button

Operation

Function

1x short

Absent setting (same as low setting)

1

1x short

Setting 1 (low setting)

2

1x short

Setting 2 (medium setting)

3

1x short

Setting 1 (low setting)

1x short

Setting 3 (timer mode) temporary 15 minutes

2x short

Setting 3 (timer mode) temporary 30 minutes

3x short

Setting 3 (timer mode) temporary 60 minutes

auto

1x short

Automatic mode 

Summary of Contents for HRC-300-EcoMax

Page 1: ...ems This manual contains important information about the operation and maintenance of the ventilation unit with heat recovery remote control CO2 room sensor and CO2 control sensor The installer manual...

Page 2: ...2 Index 1 Safety instructions 4 2 General operation of balanced ventilation system 5 3 Product information 7 4 Operating the unit 8 5 Maintenance 11 6 Malfunctions 15 7 Certification and warranty 18...

Page 3: ...es with a properly isolated home As you need enough fresh air in your home the airflow needs to be constant You require approximately 25m of fresh air an hour so good ventilation is a necessity Just o...

Page 4: ...ion all parts that may lead to personal injury are safely contained inside the housing Do not open the housing Always follow the safety instructions warnings comments and instructions in this manual F...

Page 5: ...on of the polluted air to and from the unit 6 Roof outlet incl airtight connection 7 Wall transit In balance The HRC EcoMax MaxComfort is equipped with two fan modules an extractor ventilator and a su...

Page 6: ...ure sensor which measures the moisture content in the extracted air from the kitchen bathroom and toilet If the built in humidity sensor detects that the humidity is rising for example during cooking...

Page 7: ...r flow rate m h at max 200 Pa 300 300 400 400 500 500 Tube connection mm 150 150 180 180 180 180 Preheater no yes no yes no yes Filter class ISO16890 2x coarse 65 supply ePM1 70 extract coarse 65 2x c...

Page 8: ...thin the home Setting 3 High High setting For use during cooking showering or parties 4 2 Operation using RF remote control The balance ventilator can be operated using a wireless remote control 15 RF...

Page 9: ...l using the CO2 Room sensor This sensor measures the CO2 concentration air quality in the room and makes the unit ventilate more if necessary This avoids unnecessary ventilation which benefits the ene...

Page 10: ...ased on moisture and CO2 1 Setting 1 Temporary low setting 60 min 2 Setting 2 Temporary medium setting 60 min 3 Setting 3 Temporary high setting 60 min CO2 Plus system It is possible to have a CO2 Roo...

Page 11: ...er 3 years Installer Clean ventilators 1x per 3 years Installer Clean condensation extractor 1x per 3 years Installer Clean the heat exchanger 1x per 5 years Installer Clean the inside of the unit 1x...

Page 12: ...ns can also be found on the top of the unit 5 Replace the filter handles in the recess on the front of the unit On the inside of the covers you will see an L or R marking to indicate on which side the...

Page 13: ...ing a hinge movement Caution Do not throw empty batteries into the household waste but take them to the collection points for chemical waste Maintenance CO2 Room sensor Control sensor The CO2 Room sen...

Page 14: ...14 User maintenance log Date Action Clean filters Clean valves Clean controls Fill condensation extractor...

Page 15: ...reen Battery almost empty 1x orange 2x green Reset remote control carried out 2x orange Filter indication active 3x orange II CO2 Room sensor 15RF When the status LED on the CO2 If the room sensor is...

Page 16: ...e Overview of indications on display circuit board Indication Message on display circuit board Configuration mode active continuous green In operation 1x green Start up unit RF communication 1x orange...

Page 17: ...ter warning on the display is an indication to clean or replace the filters on time When the chosen interval time in the printed circuit board has elapsed it will send a signal to the display on the u...

Page 18: ...this must be reported to the installer State the type and serial number which can be found on the type sticker under the unit Orcon bv reserves the right to change the construction and or configurati...

Page 19: ...19...

Page 20: ...Landjuweel 25 3905 PE Veenendaal Postbus 416 3900 AK Veenendaal t 31 0 318 54 47 00 info orcon nl www orcon nl...

Reviews: