MNL940-003-000- 

 

 
 

CLAIM FOR DAMAGE IN SHIPMENT

 

 
Under the FOB factory terms of sale, ownership and responsibility are transferred to the customer 
when the equipment leaves the factory. Each Behlman product is shipped from the factory in proper 
operating condition. 
 
Immediately upon receiving equipment, unpack and inspect it for evidence of damage incurred in 
shipment. File a claim with the freight carrier if the equipment has been damaged in any way or it 
fails to operate properly. Forward a copy of the damage claim report to Behlman. Include the model 
number, serial number and date the shipment was received. Behlman will advise the disposition of 
the equipment and will arrange for necessary repair or replacement. 
 
 

RETURNING EQUIPMENT TO FACTORY

 

 

Do not return equipment to the factory without prior authorization from Behlman. 

A RETURN MATERIAL AUTHORIZATION NUMBER (RMA) is required to return equipment. 

 
This equipment, like all precision electronic equipment, is susceptible to shipping damage. It 
contains heavy magnetic components as well as delicate electronic components.  
 
If equipment is returned without prior authorization, the shipment will be refused, the customer 
being liable for all shipping, handling and repair costs. 
 
When packing for reshipment, use the original shock absorbent material and shipping container to 
preclude damage to the equipment. 
 
Insure that the return authorization numbers (RMA) is available on the container for identification. 
 
 

SHIPPING INSTRUCTIONS

 

 
 

RACK MOUNTED UNITS 

 
1) 

Box(es) must be double wall with minimum 350 lbs. bursting test. 

2) 

Box(es) must provide for a minimum of 3 to 4 inches of clearance around sides, top and 
bottom of unit. 

3) 

When packing unit, utilize either a foam-in-place system or high density foam. Clearance 
provided for above must be completely filled with foam. 

 
 

FAILURE TO COMPLETELY SECURE UNIT IN BOX WILL ALLOW 
MOVEMENT DURING SHIPPING, RESULTING IN DAMAGE.

 

 
4) 

Secure box(es) to pallet(s). This is necessary to insure proper handling and protection 
during shipping. 

5) 

Place the following warning label on box(es) 

 
 

DO NOT STACK

 

 
6) 

Ship unit(s) using a freight cargo carrier; air or ground. 

 
 

CABINET MOUNTED UNITS 

 
Cabinet mounted units require that a special crate be used. The crate should be manufactured of 
plywood (3/8" or thicker) and reinforced (using 1 x 3 or larger pine) on all edges. The unit must be 
firmly secured to the crate’s base. The crate must be shock mounted to avoid damage during 
shipping. Detail drawings for Behlman's crates are available upon request. 

Summary of Contents for BEHLMAN INV 1210

Page 1: ...SERVICE ASSISTANCE CONTACT BEHLMAN CUSTOMER SERVICE DEPARTMENT PHONE TOLL FREE 1 800 874 6727 OR WRITE BEHLMAN CUSTOMER SERVICE DEPARTMENT 80 CABOT COURT HAUPPAUGE NY 11788 PHONE 631 435 0435 FAX 631...

Page 2: ...sence of flammable gases or fumes Operation of any electrical instrument in such an environment constitutes a definite safety hazard KEEP AWAY FROM LIVE CIRCUITS Operating personnel must not remove eq...

Page 3: ...itions due to the exposure of hazardous voltage that can be lethal if contacted Neither Behlman Electronics Hauppauge NY USA nor any of the subsidiary sales organizations can accept any responsibility...

Page 4: ...used the customer being liable for all shipping handling and repair costs When packing for reshipment use the original shock absorbent material and shipping container to preclude damage to the equipme...

Page 5: ...horization RMA number This number must be attached to the equipment sent back for warranty repair Equipment must be shipped back to Behlman prepaid No collect shipments will be accepted Behlman shall...

Page 6: ...3 0 OPERATING INSTRUCTIONS 3 1 Installation 3 2 Wiring 3 3 Controls and Indicators 3 4 Optional alarm contacts 4 0 OPERATIONAL CONSIDERATIONS 4 1 Load Limitations 4 2 Powering Reactive Loads 4 3 Powe...

Page 7: ...switch to AC when the DC input is lost The second option A1 will favor the AC line input and will switch to the inverter if the line is lost These features allow the unit to be incorporated into a us...

Page 8: ...e peak value of a 120Vac rms This type of waveform is known as Modified sinewave The control circuitry on the output inverter assembly also provides protective functions Output current is measured and...

Page 9: ...k mounting it is permissible to mount the inverter by the mounting ears only If the unit is intended for use in a mobile or other high vibration application the use of additional support for the rear...

Page 10: ...will place one side of the inverter output at the neutral potential It should be noted that this is only recommended to satisfy the NEC requirements The output of the inverter is isolated from the DC...

Page 11: ...Pull in cooling air min 3 clearance 3 STATUS LEDs Indicate presence of AC IN DC IN and INVERTER status optional 4 LINE BYPASS FUSE Protects input line when used as stand by Supply optional 5 OUTPUT C...

Page 12: ...MNL940 003 000 11 CONTROLS AND INDICATORS MODEL INV 1210 SERIES INVERTERS ALL MODELS...

Page 13: ...ch all loads off before switching on the inverter This will prevent multiple in rush currents from tripping protective circuits in the inverter 2 Switch on the inverter At this point the sound of the...

Page 14: ...thod is to insert a limiting impedance in series with the load This could be in the form of a fixed resistor or NTC negative temperature coefficient thermistor Also zero crossing switching can be empl...

Page 15: ...n doubt consult the motor manufacturer 4 6 POWERING NON LINEAR LOADS Loads utilizing rectifiers and SCRs interact with the AC power source and have a profound effect on the output waveform Consider th...

Page 16: ...quipment These devices require a sinusoidal voltage for proper operation and timing It should be noted that this unit produces a waveform with square edges These waveform produce harmonics at frequenc...

Page 17: ...sure AC input at rear panel Output distorted high peak load current Reduce loading if distortion is objectional DC breaker repeatedly trips DC polarity reversed or internal fault in inverter Check pol...

Page 18: ...MNL940 003 000 17 6 0 MECHANICAL OUTLINE...

Page 19: ...MNL940 003 000 18 REVISION HISTORY Rev ECO DESCRIPTION DATE N A INITIAL RELEASE 5 9 2016...