12
To configure the rated power of the installation, manually adjust the circuit
indicated in the following image.
The position of the rotary circuit defines the maximum current of the
installation, this parameter must be configured according to the rated power in
the installation as shown in the following table.
This adjustment is fundamental for the correct operation of the load modulator.
Single-phase
Current/Power
Three-phase
Current/Power
Unlimited
Unlimited
10 A/2.3 kW
10 A/6.928 kW
13 A/3 kW
13 A/9 kW
15 A/3.45 kW
15 A/10.392 kW
18 A/4.14 kW
18 A/12.42 kW
20 A/4.6 kW
20 A/13.856 kW
23 A/5.3 kW
23 A/15.9 kW
25 A/5.75 kW
25 A/17.321 kW
28 A/6.44 kW
28 A/19.32 kW
30 A/6.9 kW
30 A/20.785 kW
35 A/8.05 kW
35 A/24.249 kW
40 A/9.2 kW
40 A/27.713 kW
45 A/10.35 kW
45 A/31.177 kW
50 A/11.5 kW
50 A/34.641 kW
55 A/12.65 kW
55 A/37.95 kW
63 A/14.49 kW
63 A/43.648 kW
If the
TMC100
transformer is not installed, the position of the rotary circuit
must be in position NO LIMIT. in order not to limit the load current.
Summary of Contents for VIARIS COMBI
Page 1: ...1 VIARIS COMBI CARGADOR INTELIGENTE DE VEH CULO EL CTRICO...
Page 15: ...15...
Page 25: ...1 VIARIS COMBI STAZIONE DI CARICA IN AC PER VEICOLI ELETTRICI...
Page 26: ...2...
Page 39: ...15...
Page 49: ...1 VIARIS COMBI EV SMART CHARGER FOR PRIVATE ENVIRONMENTS...
Page 50: ...2...
Page 63: ...15...
Page 73: ...1 VIARIS COMBI CHARGEUR INTELLIGENT VE POUR ENVIRONNEMENTS PRIV S...
Page 74: ...2...
Page 87: ...15...
Page 97: ...1 VIARIS COMBI CARREGADOR INTELIGENTE DE VE CULO EL TRICO...
Page 111: ...15...